| Special Service Tool |
|
Tool Name / Number |
Illustration |
Description |
|
High voltage Battery Module Assembly (BMA) transport hanger TKS - 2301 |
|
Used to transferring the high voltage Sub Battery Pack Assembly (Sub-BPA) and Battery Module Assembly (BMA) |
|
High voltage battery module surface pressure jig 09375 - GI800 |
|
Used for compressing the high voltage Sub Battery Pack Assembly (Sub-BPA) |
|
High voltage battery module guide 09375 - GI900 |
|
Used for seating the high voltage battery module on the surface pressure jig |
|
High voltage battery module disassembly jig TMS - 1907 |
|
Used for disassembling the high voltage Sub Battery Pack Assembly (Sub-BPA) |
| Removal |
|
Do not step on or apply a load when removing the Sub Battery Pack Assembly (Sub-BPA). The lower part of the
Sub-BPA may break if a load is applied.
|
|
| 1. |
Remove the Battery System Assembly (BSA) upper case.
(Refer to High Voltage Battery System - "Case")
|
| 2. |
Remove the main fuse negative ( - ) bus bar (A) after removing the bolt and nut.
|
| 3. |
Remove the FR junction box to Power Relay Assembly (PRA) bus bars (A) after removing the bolts and nuts.
|
| 4. |
Disconnect the all Cell Monitoring Unit (CMU) voltage & temperature sensing connector (A).
|
| 5. |
Disconnect the Battery Management Unit (BMU) wiring connector (A).
|
| 6. |
Remove the voltage & temperature sensing wiring (A) after removing the wiring clip from the CMU.
|
| 7. |
Remove the battery terminal pad (A)
|
| 8. |
Disconnect the voltage & temperature sensing wiring connectors (A) and remove the fixing clips (B).
|
| 9. |
Remove the battery module bus bars (A) after removing the bolts.
|
| 10. |
Install the battery terminal cover (TKS - 2301) (A).
|
| 11. |
Remove the mounting bracket (A) after removing the bolts.
|
| 12. |
Remove the bolts and nuts of Sub Battery Pack Assembly (Sub-BPA) (A).
|
| 13. |
Install the high voltage battery module assembly hanger (TKS - 2301) in the Sub-BPA.
|
| 14. |
Transfort the Sub-BPA (A) using the crane jack.
|
| 15. |
Install the removed Sub-BPA (A) on high voltage battery module assembly disassembly jig (TMS - 1907).
|
| 16. |
Remove the remaining gap filler on the Sub-BPA downside surface and the lower case.
|
| Installation |
|
| 1. |
Perform the cell balancing procedures when the Battery Module Assembly (BMA) is replaced with a new one.
(Refer to High Voltage Battery System - "Battery Module Assembly
(BMA)")
|
| 2. |
Apply a new gap filler with the Special Service Tool (SST).
(Refer to High Voltage Battery System - "Gap Filler
Application")
|
| 3. |
Install in the reverse order of removal.
|
| 4. |
Perform the High Voltage Battery Pack Connector Check with the KDS before installing the Battery System
Assembly (BSA) upper case.
(S/W Management → Battery Management System (BMS) → High Voltage Battery Pack Connector Check)
|
| 5. |
Perform the air tightness inspection with the KDS.
(Refer to High Voltage Battery System - "Air Tightness
Inspection")
|
| 6. |
Perform the SOC calibration with the KDS.
(S/W management → Battery Management System (BMS) → SOC Calibration)
|
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: General Service Information
General Information General Service Information 1. Protect the vehicle's protective painted surfaces and internal parts with work covers (seat covers) or tape (if damaged by tools) to prevent damage. Before closing the hood, check the PE room for any tools or parts left.Used high voltage battery system storage, transportation, disposal guide • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training.