Kia EV6: High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) Removal and Installation

Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual / Battery Control System (Standard) / High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) Removal and Installation

Special Service Tool
Tool Name / Number
Illustration
Description
High voltage Battery Module Assembly (BMA) transport hanger
TKS - 2301

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Special Service Tool illustration

Used to transferring the high voltage Sub Battery Pack Assembly (Sub-BPA) and Battery Module Assembly (BMA)
High voltage battery module surface pressure jig
09375 - GI800

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Special Service Tool illustration

Used for compressing the high voltage Sub Battery Pack Assembly (Sub-BPA)
High voltage battery module guide
09375 - GI900

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Special Service Tool illustration

Used for seating the high voltage battery module on the surface pressure jig
High voltage battery module disassembly jig
TMS - 1907

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Special Service Tool illustration

Used for disassembling the high voltage Sub Battery Pack Assembly (Sub-BPA)

Removal
Warning
•
When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
•
When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
•
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
Note
Do not step on or apply a load when removing the Sub Battery Pack Assembly (Sub-BPA). The lower part of the Sub-BPA may break if a load is applied.
Information
•
Install the high voltage battery module surface pressure jig and guide before using the high voltage battery module disassembly jig. (Refer to the equipment manufacturer's manual)
•
The procedure for removing the Sub Battery Pack Assembly (Sub-BPA) below is for #1. Other Sub-BPAs are performed in the same procedures.

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

1.
Remove the Battery System Assembly (BSA) upper case.
(Refer to High Voltage Battery System - "Case")
2.
Remove the main fuse ( - ) bus bar (A) after removing the bolt and nut.

Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

3.
Remove the front junction box ↔ Power Relay Assembly (PRA) bus bars (A) after removing the bolts and nuts.

Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

4.
Remove the PRA ↔ battery module bus bar (A) after removing the bolt and nut.

Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

5.
Remove the Sub Battery Pack Assembly (Sub-BPA) bus bar (A) after removing the bolts.

Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

Information
1)
Remove the main fuse ( + ) bus bar (A) after removing the bolt and nut when removing the Sub-BPA #3, 4.

Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

2)
Remove the Cell Monitoring Unit (CMU) fasteners (A) when removing the Sub-BPA #3, 4.

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

3)
Remove the battery module terminal pad (A) when removing the Sub-BPA #3, 4.

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

6.
Remove the battery module bus bars (A) after removing the bolts.

Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

7.
Install the battery terminal cover (TKS - 2301) (A).

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

Note
•
Be sure to install the battery terminal cover (TKS - 2301) to prevent safety accidents caused by contact with objects.
•
Install the battery ( - ) terminal.
8.
Disconnect the voltage & temperature sensing wiring connectors (A) and remove the fixing clips (B).

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

9.
Remove the mounting bracket (A) after removing the bolts.

Tightening torque
Step 1 : 8.8 N·m (0.9 kgf·m, 6.5 lb·ft)
Step 2 : 10.8 N·m (1.1 kgf·m, 8.0 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

10.
Remove the bolts and nuts of Sub-BPA (A).

Tightening torque
Step 1 : 8.8 N·m (0.9 kgf·m, 6.5 lb·ft)
Step 2 : 10.8 N·m (1.1 kgf·m, 8.0 lb·ft)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

11.
Install the high voltage attery Module Assembly (BMA) transport hanger (TKS - 2301) to Sub-BPA (A).

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

Note
•
The removed Sub-BPA is installed and worked on the high voltage battery module assembly disassembly jig (TMS - 1907).
•
Note for handling as damage and deformation on the lower side of the Sub-BPA may cause fire.

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

Information
Refer to the equipment manufacturer's manual for how to use High voltage Battery Module Assembly (BMA) transport hanger (TKS - 2301).
12.
Remove the Sub-BPA (A) using the crane jack.

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

13.
Install the removed Sub-BPA (A) to the high voltage battery module assembly disassembly jig (TMS - 1907).

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Removal illustration

Information
For detailed instructions on how to use it, refer to the manual of manufacturer of Battery Module Disassembly jig (TMS - 1907).
14.
Remove the remaining gap filler on the Sub-BPA downside surface and the lower case.
Note
•
Carefully remove the gap filler so that the lower part of the module is not deformed after wearing the insulating gloves.
•
Remove with the plastic remover to prevent scratches on the lower case.
•
Be careful not to contact the bottom of the module when the air gun is used.
Installation
Warning
•
When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
•
When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
•
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
1.
Perform the cell balancing procedures when the Battery Module Assembly (BMA) is replaced with a new one.
(Refer to High Voltage Battery System - "Battery Module Assembly (BMA)")
2.
Apply a new gap filler with the Special Service Tool (SST).
(Refer to High Voltage Battery System - "Gap Filler Application")
3.
Install in the reverse order of removal.
Note
•
Install the Sub Battery Pack Assembly (Sub-BPA) to the specified torque.
•
If the Sub-BPA is dropped, it may cause internal damage. (Do not reuse)
•
Do not reuse the bus bar mounting bolts. (Loctite applied)

Battery Control System (Standard) — High Voltage Battery System / Sub-Battery Pack Assembly (Sub-BPA) / Removal and Installation / Installation illustration

4.
Perform the High Voltage Battery Pack Connector Check with the KDS before installing the Battery System Assembly (BSA) upper case.
(S/W Management → Battery Management System (BMS) → High Voltage Battery Pack Connector Check)
5.
Perform the air tightness inspection with the KDS.
(Refer to High Voltage Battery System - "Air Tightness Inspection")
6.
Perform the SOC calibration with the KDS.
(S/W management → Battery Management System (BMS) → SOC Calibration)
Information
Refer to the KDS screen for operating conditions and details.

Other information:

Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: When the Approach unlock is activated

When approaching the Kia EV6 within approximately 1 ft. (30 cm) of either the driver’s or front passenger’s door while carrying the registered smart key, the exterior door handles automatically extend outward and the doors unlock for convenient entry. At the same time, the hazard warning lights flash twice and the confirmation chime sounds twice, notifying the driver that the Kia EV6 has recognized the smart key and unlocked the vehicle successfully.

Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Parking

While parking, the rear view of the Kia EV6 Surround View Monitor is activated under the following conditions: The gear is in P (Park), N (Neutral), or D (Drive), the Kia EV6 speed is below 6 mph (10 km/h), and the Parking/View button (1) is pressed. The driver can then press the view switching button (2) to select the rear camera view.