Kia EV6: Heating,Ventilation And Air Conditioning / Air Conditioning System
Contents:
Description and Operation
| Description and Operation |
The heat pump system converts the flow of refrigerant to enable cooling/heating, minimizing battery consumption
during heating and improving the driving distance of the electric vehicle.
Cooling Mode Refrigerant Flow Sequence
| 1. |
An electric compressor compresses the refrigerant.
|
| 2. |
The compressed high-temperature, high-pressure refrigerant passes through the inner condenser. (there is no
heat exchange with the vehicle interior)
|
| 3. |
The compressed high-temperature, high-pressure refrigerant passes through the heat pump EXV without
expansion. (dehumidification EXV is closed)
|
| 4. |
The compressed high-temperature, high-pressure refrigerant transfers heat to the water-cooled condenser and
is condensed.
|
| 5. |
The refrigerant 3-way valve opens toward the outer condenser.
|
| 6. |
As the refrigerant passes through the outer condenser, it releases heat to the atmosphere and is further
condensed.
|
| 7. |
Refrigerant expansion in SOL & TXV (SOL open, high voltage battery chiller EXV closed)
|
| 8. |
The expanded, low-temperature, low-pressure refrigerant absorbs heat from the vehicle interior in the
evaporator.
|
| 9. |
The refrigerant that absorbs heat from inside the vehicle sends only gaseous refrigerant from the
accumulator to the electric compressor.
|
|
•
|
TXV : Thermal Expansion Valve
|
|
Battery-Only Cooling Mode
| 1. |
An electric compressor compresses the refrigerant.
|
| 2. |
The compressed high-temperature, high-pressure refrigerant passes through the inner condenser. (there is no
heat exchange with the vehicle interior)
|
| 3. |
The compressed high-temperature, high-pressure refrigerant passes through the heat pump EXV without
expansion. (dehumidification EXV is closed)
|
| 4. |
The compressed high-temperature, high-pressure refrigerant transfers heat to the water-cooled condenser and
is condensed.
|
| 5. |
The refrigerant 3-way valve opens toward the outer condenser.
|
| 6. |
As the refrigerant passes through the outer condenser, it releases heat to the atmosphere and is further
condensed.
|
| 7. |
Refrigerant expansion in battery chiller. (EXV duty control, SOL & TXV solenoid valve closed)
|
| 8. |
The battery chiller absorbs heat from the high voltage battery and the refrigerant expands
|
| 9. |
The refrigerant that absorbs heat from inside the vehicle sends only gaseous refrigerant from the
accumulator to the electric compressor.
|
|
•
|
TXV : Thermal Expansion Valve
|
|
Interior + Battery Cooling Mode
| 1. |
An electric compressor compresses the refrigerant.
|
| 2. |
The compressed high-temperature, high-pressure refrigerant passes through the inner condenser. (there is no
heat exchange with the vehicle interior)
|
| 3. |
The compressed high-temperature, high-pressure refrigerant passes through the heat pump EXV without
expansion. (dehumidification EXV is closed)
|
| 4. |
The compressed high-temperature, high-pressure refrigerant transfers heat to the water-cooled condenser and
is condensed.
|
| 5. |
The refrigerant 3-way valve opens toward the outer condenser.
|
| 6. |
As the refrigerant passes through the outer condenser, it releases heat to the atmosphere and is further
condensed.
|
| 7. |
Refrigerant expansion in SOL & TXV (solenoid valve open), Refrigerant expansion in battery chiller.
(EXV duty control)
|
| 8. |
The expanded low-temperature, low-pressure refrigerant absorbs heat from the vehicle interior in the
evaporator and absorbs heat from the battery coolant in the battery chiller.
|
| 9. |
The refrigerant that absorbs heat from inside the vehicle sends only gaseous refrigerant from the
accumulator to the electric compressor.
|
|
•
|
TXV : Thermal Expansion Valve
|
|
Heating Mode Refrigerant Flow Sequence
| 1. |
An electric compressor compresses the refrigerant.
|
| 2. |
When the compressed high-temperature and high-pressure refrigerant passes through the inner condenser, the
mix door opens to the heating side to dissipate heat.
|
| 3. |
The compressed high-temperature, high-pressure refrigerant works as an expansion valve through a small hole
in the heat pump EXV. (the dehumidification EXV is closed)
|
| 4. |
The expanded low-temperature and low-pressure refrigerant absorbs heat from the PE system in the
water-cooled condenser.
|
| 5. |
Refrigerant 3-way valve opens in the direction of bypassing the outer condenser to minimize heat loss in
the refrigerant.
|
| 6. |
Refrigerant that has absorbed heat from the drive (PE) system sends only gaseous refrigerant from the
accumulator to the electric compressor.
|
|
•
|
TXV : Thermal Expansion Valve
|
|
Heating & Dehumidification Mode
| 1. |
An electric compressor compresses the refrigerant.
|
| 2. |
When the compressed high-temperature and high-pressure refrigerant passes through the inner condenser, the
mix door opens to the heating side to dissipate heat.
|
| 3. |
The compressed high-temperature, high-pressure refrigerant works as an expansion valve through a small hole
in the heat pump EXV.
|
| 4. |
The dehumidification EXV opens and a portion of the expanded refrigerant passes through the evaporator to
remove moisture from the room air.
|
| 5. |
The expanded low-temperature and low-pressure refrigerant absorbs heat from the PE system in the
water-cooled condenser.
|
| 6. |
Refrigerant 3-way valve opens in the direction of bypassing the outer condenser to minimize heat loss in
the refrigerant.
|
| 7. |
Refrigerant that has absorbed heat from the drive PE system sends only gaseous refrigerant from the
accumulator to the electric compressor. (refrigerant that has been partially divided to dehumidify the indoor
air is recombined)
|
|
•
|
TXV : Thermal Expansion Valve
|
|
Components and Components Location. A/C Transducer Description and Operation
Components and Components Location
[2WD]
1. Suction & Liquid Hose Assembly 1-a. 7.8 - 11.8
N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 1-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 1-c. 7.8
- 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 1-d. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 2.
Chiller 2-a. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 3. Discharge Hose 3-a. 8.8 - 13.7 N·m
(0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 3-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 3-c. 7.8 -
11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 3-d. 21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft) 4.
Suction Hose Assembly 2 4-a. 21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft) 4-b. 8.8 - 13.7 N·m (0.9
- 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
5. Suction Hose Assembly 1 5-a. 21.6 - 32.4 N·m (2.2
- 3.3 kgf·m, 15.9 - 23.9 lb·ft) 5-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 6. Water
Condenser 6-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 6-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m,
6.5 - 10.1 lb·ft) 7. Electric A/C Compressor 7-a. 19.6 - 33.3 N·m (2.0 - 3.4 kgf·m, 14.5 - 24.6
lb·ft) 8. Condenser Pipe 8-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 9. Condenser 9-a.
4.9 - 7.8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft) 10. Accumulator 10-a. 9.8 - 14.7 N·m (1.0 - 1.5 kgf·m,
7.2 - 10.8 lb·ft)
|
[4WD]
1. Suction & Liquid Hose Assembly 1-a. 7.8 - 11.8
N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 1-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 1-c. 7.8
- 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 1-d. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 2.
Chiller 2-a. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 3. Discharge Hose 3-a. 8.8 - 13.7 N·m
(0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 3-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 3-c. 7.8 -
11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 3-d. 21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft) 4.
Suction Hose Assembly 2 4-a. 2.2 ~ 3.3 kgf·m 4-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
5. Suction Hose Assembly 1 5-a. 8.8 - 13.7 N·m (0.9 -
1.4 kgf·m, 6.5 - 10.1 lb·ft) 6. Water Condenser 6-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
6-b. 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft) 7. Electric A/C Compressor 7-a. 19.6 - 33.3
N·m (2.0 - 3.4 kgf·m, 14.5 - 24.6 lb·ft) 8. Condenser Pipe 8-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7
lb·ft) 9. Condenser 9-a. 4.9 - 7.8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft) 10. Accumulator 10-a. 9.8
- 14.7 N·m (1.0 - 1.5 kgf·m, 7.2 - 10.8 lb·ft)
|
A/C Transducer Description and Operation
Measure the pressure and temperate of the refrigerant line and convert it into a voltage value. It optimizes and
protects the air conditioner system by controlling the operation of the compressor using the converted voltage value.
A/C Transducer Removal and Installation
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "High Voltage
System General Safety Information and Caution". If not, it may cause serious accidents such as
electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
A/C Transducer - Non Heat Pump
| 1. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 2. |
Remove the auxiliary 12 V battery tray.
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
2WD")
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
4WD")
|
| 3. |
Remove the A/C transducer.
Tightening torque :
9.8 - 11.8 N·m (1.0 - 1.2 kgf·m, 7.2 - 8.7 lb·ft)
|
[Temperature - 2WD]
| (1)
|
Disconnect the A/C transducer connector (A).
|
| (2)
|
Remove the A/C transducer (A).
|
[Pressure - 2WD]
| (1)
|
Remove the A/C transducer (B) after disconnecting the A/C transducer connector (A).
|
[Temperature - 4WD]
| (1)
|
Remove the A/C transducer (B) after disconnecting the A/C transducer connector (A).
|
[Pressure - 4WD]
| (1)
|
Remove the A/C transducer (B) after disconnecting the A/C transducer connector (A).
|
|
Be careful not to bend the liquid suction pipe.
|
|
A/C Transducer - Heat Pump
| 1. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 2. |
Remove the auxiliary 12 V battery tray.
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
2WD")
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
4WD")
|
| 3. |
Remove the A/C transducer.
Tightening torque :
9.8 - 11.8 N·m (1.0 - 1.2 kgf·m, 7.2 - 8.7 lb·ft)
|
[Temperature - 2WD]
| (1)
|
Remove the A/C transducer (B) after disconnecting the A/C transducer connector (A).
|
[Pressure - 2WD]
| (1)
|
Remove the A/C transducer (B) after disconnecting the A/C transducer connector (A).
|
[Temperature - 4WD]
| (1)
|
Disconnect the A/C transducer connector (A).
|
| (2)
|
Remove the A/C transducer (A).
|
[Pressure - 4WD]
| (1)
|
Remove the A/C transducer (B) after disconnecting the A/C transducer connector (A).
|
|
Be careful not to bend the liquid suction pipe.
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
•
|
When installing, replace the O-ring with a new one.
|
|
•
|
Charge the refrigerant system and test the air conditioner performance.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
|
Ambient Temperature Sensor Description and Operation
|
•
|
It detects the temperature of the air outside the vehicle and converts it into a resistance value. It is a
negative temperature coefficient (NTC) thermistor type in which the resistance value decreases when the
temperature rises and the resistance value increases when the temperature decreases.
|
|
•
|
It controls discharge temperature, sensor calibration, temperature control actuator, blower motor, and mode
control actuator of the heater and air conditioner system.
|
Ambient Temperature Sensor Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
Ambient Temperature Sensor
| 1. |
Remove the front bumper assembly.
(Refer to Body - "Front Bumper Assembly")
|
| 2. |
Disconnect the ambient temperature sensor connector (A).
|
| 3. |
Remove the ambient temperature sensor (A).
|
Clip position :
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Ambient Temperature Sensor Inspection. Auto Defogging Sensor Description and Operation
Ambient Temperature Sensor Inspection
| 1. |
Change the temperature around the ambient temperature sensor and check if the resistance value of 1 - 2
terminals changes.
1. Ambient Sensor ( + )
|
2. Sensor Ground
|
Sensor resistance
Temperature [°C (°F)]
|
Resistance (KΩ)
|
-30 (-22)
|
480.41
|
-20 (-4)
|
271.21
|
-10 (14)
|
158.18
|
0 (32)
|
95.10
|
10 (50)
|
58.80
|
20 (68)
|
37.32
|
30 (86)
|
24.26
|
40 (104)
|
16.13
|
50 (122)
|
10.95
|
|
Auto Defogging Sensor Description and Operation
When the auto defogging sensor detects moisture on the windshield glass, it automatically removes the moisture by
activating the auto defogging actuator.
Auto Defogging Sensor Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Turn the POWER OFF, separate the auxiliary battery (12 V) ( - ) terminal, and disconnect the high voltage
service interlock connector.
| (1)
|
Open the front trunk (A).
|
| (2)
|
Open the auxiliary 12 V battery service cover (A).
|
| (3)
|
Turn the POWER OFF, separate the auxiliary battery (12 V) ( - ) terminal (A).
Tightening torque :
7.8 - 9.8 N·m (0.8 - 1.0 kgf·m, 5.8 - 7.2 lb·ft)
|
|
| (4)
|
Disconnect the service interlock connector (A).
|
•
|
Wait more than 5 minutes for capacitor of the high voltage battery system to be
discharged completely.
|
|
•
|
When working on a vehicle during discharging the capacitor, it can cause an
electrical shock or injury, so follow the manual.
|
|
|
The service interlock connector cannot be completely removed.
|
|
|
| 2. |
Remove the multi sensor cover.
(Refer to Body - "Multi Sensor Cover")
|
| 3. |
Disconnect the auto defogging sensor connector (A).
|
| 4. |
Remove the auto defogging sensor (A).
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Chiller Description and Operation
It is a heat pump system that exchanges low-temperature refrigerant by using waste heat from the motor.
Chiller Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
|
If the air conditioner is operational, run it for a few minutes.
|
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Drain the coolant.
(Refer to Electric Vehicle Cooling System - "Coolant")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Separate the chiller hose (A).
|
| 5. |
Remove the chiller inlet line (A) and chiller outlet line (A) after removing the bolts.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
When disconnecting the line, put a plug or cap on the system immediately to protect it from
moisture and dust.
|
|
| 6. |
Remove the chiller (A) after removing the bolts.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Be sure to inject the specified refrigerant (R-1234yf) and refrigeration oil (POE) by using the
refrigerant recovery/charging equipment dedicated to the electric compressor. Compressor damage and
safety accidents may occur if refrigeration oil (PAG) of general vehicles is mixed.
|
|
•
|
When installing a single unit, install it to the specified torque.
|
|
•
|
Check for refrigerant leaks by using a gas leak detector.
|
|
•
|
Charge the refrigerant after removing the air in the cooling system.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
|
Compressor Oil Inspection
|
•
|
Oil is used to lubricate the compressor.
|
|
•
|
Since the oil circulates into the system during the operation of the compressor, the oil must be
replenished to maintain the total capacity of the original oil when replacing the parts in the system or when
a large capacity of gas is leaked.
|
Total amount of oil in the system : REF POE-1 180 ± 10 g (6.35 ±
0.35 oz.)
|
|
Kia Approved : RB100EV (JX Energy), Domestic ND 11 (DENSO)
|
Compressor Oil Handling Tips
|
•
|
Prevent moisture, dust and metal particles from entering the oil.
|
|
•
|
Do not mix compressor oil.
|
|
•
|
If the oil is left in the air for a long time after using it, the oil absorbs moisture, so be sure to close
the container immediately after use.
|
Compressor Oil Check and Adjustment
| 1. |
Oil return operation
| (1)
|
Set to maximum cooling, blower speed, and run the compressor for 20 - 30 minutes to restore oil to
the compressor.
|
|
| 2. |
Before putting oil into the compressor in use, the compressor oil must be checked in the following order.
| (1)
|
Turn off the IG after performing the oil return operation.
|
| (2)
|
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| (3)
|
Remove the electric A/C compressor.
(Refer to Air Conditioning System - "Electric Air Conditioning
Compressor - Non Heat Pump")
(Refer to Air Conditioning System - "Electric Air Conditioning
Compressor - Heat Pump")
|
| (4)
|
Drain the compressor oil.
|
If the drained oil amount is below 70 cc the oil has leaked so perform a leak test.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
| (5)
|
Adjust the oil level after checking the oil for contamination.
Amount of drained oil
|
Oil supplement
|
higher than 70 cc
|
Add the capacity of the oil drained.
|
less than 70 cc
|
Add 70 cc.
|
|
•
|
When exchanging an electric A/C compressor replenish or drain oil according to the
difference in weight between the old and new parts before installing it.
|
|
•
|
When the oil in the air conditioning system is insufficient the durability of the
electric A/C compressor deteriorates.
|
|
•
|
If there is a lot of oil in the air conditioning system the performance of the air
conditioning system deteriorates.
|
|
|
|
Condenser Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Remove the radiator upper air guard and lower air guard.
(Refer to Cooling System - "Radiator")
|
| 3. |
Remove the condenser pipe (A) after removing the nuts.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
| 4. |
Remove the condenser (A) after removing the bolts.
Tightening torque :
4.9 - 7.8 N·m (0.5 - 0.8 kgf·m, 3.6 - 5.8 lb·ft)
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
•
|
If a new condenser is installed, replenish the compressor oil (POE OIL).
|
|
•
|
Replace the O-rings at each connection with new ones, and apply a few drops of compressor
oil (refrigerant oil) to the O-rings before connecting hoses or lines. To avoid leakage of
R-1234yf, use the specified O-ring.
|
|
•
|
When installing the condenser, be careful not to have an impact on the condenser pin.
|
|
•
|
Charge the refrigerant system and test the air conditioner performance.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
|
Condenser Inspection
| 1. |
Inspect the condenser pins for blockages or damage.
If the pin is clogged, clean it with water or dry it with compressed air. If the pin is bent, spread it out
with a screwdriver or pliers.
|
| 2. |
Check the condenser connection for leaks and repair or replace if necessary.
|
Electric A/C Compressor Removal and Installation - Non Heat Pump
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working on high voltage system or related components, make sure that you are familiar and
comply with the "Safety Precautions, Cautions and Warnings." If you do not comply with the
instructions, serious accidents due to electric shock or leakage may occur.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
|
If the air conditioner is operational, run it for a few minutes.
|
| 1. |
Perform the high voltage shut off procedure.
(Refer to General Information - "High Voltage Shut off
Procedure")
|
| 2. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 3. |
Remove the auxiliary 12 V battery tray.
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
2WD")
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
4WD")
|
| 4. |
Disconnect the A/C transducer connector.
(Refer to Air Conditioning System - "A/C Transducer)
|
| 5. |
Disconnect the compressor ECV connector (A) and compressor high voltage connector (B).
[2WD]
[4WD]
|
| 6. |
Remove the electric A/C compressor assembly.
[2WD]
| (1)
|
Separate the discharge hose (A) after removing the bolt.
Tightening torque
:
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
| (2)
|
Separate suction & liquid hose (A) after removing the bolt.
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (3)
|
Remove the electric A/C compressor (A) after removing the nuts.
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (4)
|
Remove the compressor mounting bracket (A) after removing the bolts.
Tightening torque
:
19.6 - 33.3 N·m (2.0 - 3.4 kgf·m, 14.5 - 24.6 lb·ft)
|
|
[4WD]
| (1)
|
Remove the discharge hose bolt (A).
Tightening torque
:
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
| (2)
|
Remove the discharge hose (A) after removing the bolt
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (3)
|
Separate the suction pipe (A) after removing the bolt.
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (4)
|
Remove the electric A/C compressor assembly (A) after removing the bolts.
Tightening torque
:
24.5 - 32.4 N·m (2.5 - 3.3 kgf·m, 18.1 - 23.9 lb·ft)
|
|
|
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working on high voltage system or related components, make sure that you are familiar and
comply with the "Safety Precautions, Cautions and Warnings." If you do not comply with the
instructions, serious accidents due to electric shock or leakage may occur.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
| 1. |
Install in reverse order of removal.
|
Be sure to inject the specified refrigerant (R-1234yf) and refrigeration oil (POE) by using the
refrigerant recovery/charging equipment dedicated to the electric compressor. Compressor damage and
safety accidents may occur if refrigeration oil (PAG) of general vehicles is mixed.
|
|
Electric A/C Compressor Removal and Installation - Heat Pump
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working on high voltage system or related components, make sure that you are familiar and
comply with the "Safety Precautions, Cautions and Warnings." If you do not comply with the
instructions, serious accidents due to electric shock or leakage may occur.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
|
If the air conditioner is operational, run it for a few minutes.
|
| 1. |
Perform the high voltage shut off procedure.
(Refer to General Information - "High Voltage Shut-off
Procedures")
|
| 2. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 3. |
Remove the auxiliary 12 V battery tray.
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
2WD")
(Refer to Battery Control System - "Auxiliary Battery (12 V) -
4WD")
|
| 4. |
Disconnect the A/C transducer connector.
(Refer to Air Conditioning System - "A/C Transducer")
|
| 5. |
Disconnect the compressor ECV connector (A) and compressor high voltage connector (B).
[2WD]
[4WD]
|
| 6. |
Remove the electric A/C compressor assembly.
[2WD]
| (1)
|
Separate the discharge hose (A) after removing the bolts.
Tightening torque
:
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (2)
|
Separate suction & liquid hose (A) after removing the bolt.
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (3)
|
Remove the electric A/C compressor (A) after removing the nuts.
Tightening torque
:
19.6 - 33.3 N·m (2.0 - 3.4 kgf·m, 14.5 - 24.6 lb·ft)
|
|
| (4)
|
Remove the compressor mounting bracket (A) after removing the bolts.
Tightening torque
:
19.6 - 33.3 N·m (2.0 - 3.4 kgf·m, 14.5 - 24.6 lb·ft)
|
|
[4WD]
| (1)
|
Separate the discharge hose (A) after removing the bolts.
Tightening torque
:
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (2)
|
Separate the suction pipe (A) after removing the bolt.
Tightening torque
:
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (3)
|
Remove the electric A/C compressor assembly (A) after removing the bolts.
Tightening torque
:
24.5 - 32.4 N·m (2.5 - 3.3 kgf·m, 18.1 - 23.9 lb·ft)
|
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
•
|
When installing a single unit, install it to the specified torque.
|
|
•
|
Perform the refrigerant leak test/vacuum/charging by using the refrigerant
recovery/recycling/charging machine.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
•
|
Perform the compressor oil inspection.
(Refer to Air conditioning System - "Compressor
Oil")
|
|
|
Electric A/C Compressor Inspection
Electric compressor inverter inspection
|
Check the circuit of the compressor controller (inverter) for leakage (faults).
|
| 1. |
How to check the pin failure of the electric compressor inverter.
| (1)
|
High voltage pin
Normal resistance value : 100 Ω or more
Abnormal resistance value : 100 Ω or less
|
|
| (2)
|
Low voltage pin
| 1) |
CAN HIGH/LOW resistance measurement
- Measure terminals 3-6.
Normal resistance value : Approx. 120 Ω
Abnormal resistance value : Short (about 0 Ω
or more than 1 kΩ)
|
|
| 2) |
CAN-GND resistance measurement
- Measure the 2rd - 6th / 2rd - 3th terminal.
Normal resistance value : 1 MΩ
Abnormal resistance value : Short (approx. 0
Ω)
|
|
| 3) |
Interlock ( + )/( - ) resistance measurement (Measure terminals 1-4 (B) after connecting
high voltage connector (A))
Normal resistance value : 1.0 Ω or less
Abnormal resistance value : ∞ MΩ
|
|
Pin number
|
Function
|
Pin number
|
Function
|
1
|
Interlock ( - )
|
4
|
Interlock ( + )
|
2
|
GND 12 V
|
5
|
IG 12 V
|
3
|
CAN Low
|
6
|
CAN High
|
|
|
|
|
Electric compressor body inspection
|
Check each power terminal connected to the 3-phase compressor motor for leakage.
|
| 1. |
Separate the inverter kit and the body kit.
(Refer to Electric A/C Compressor - "Diassembly and
Reassembly")
|
| 2. |
How to check the internal failure of the electric compressor body.
| (1)
|
Remove the low pressure pipe on the electric compressor side.
|
| (2)
|
Check for contamination of copper wire and white thread inside the compressor.
|
|
| 3. |
To check the compressor motor, measure the resistance value of the 3-phase power pin.
| (1)
|
If the 3-phase resistance value is abnormal, the motor is faulty, so replace the electric
compressor body.
Item
|
U-V phase
|
V-W phase
|
U-W phase
|
Normal Resistance Value (Ω)
|
0.4 - 0.5
|
Abnormal Resistance Value (Ω)
|
0
|
|
|
Compressor Insulation Resistance Inspection
|
Check if insulation breakdown occurs between the motor and the housing (case) .
(For example, in cases where foreign materials generated by scroll seizure contaminate the motor, causing a
short circuit and resulting in motor burnout)
|
| 1. |
Compressor Insulation Resistance
Normal resistance value : more than 100 MΩ (@500 Vdc, no
refrigerant)
|
|
Electric A/C Compressor Disassembly and Reassembly
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Remove the electric A/C compressor.
(Refer to Air Conditioning System - "Electric A/C Compressor - Non
Heat Pump")
(Refer to Air Conditioning System - "Electric A/C Compressor - Heat
Pump")
|
| 2. |
The inverter/body kit is an electronic component and can be easily damaged by dust and moisture, so move it
to a clean room.
|
•
|
Remove dust or dirt from the exterior of the compressor to prevent contamination of the
inverter/body kit.
|
|
•
|
Do not open the new inverter/body kits packaging until just before installation to prevent
contamination.
|
|
|
| 3. |
Remove the bolt (A) that fixes the inverter/body kit.
|
•
|
Do not reuse the inverter/body kit tightening bolts.
|
|
•
|
Never remove the bolts which are not marked.
|
|
|
| 4. |
Separate the inverter kit (A) and the body kit (B).
|
Be careful not to damage the 3-phase power pin (A) when removing the inverter/body kit.
|
|
| 5. |
Remove the inverter/body kit gasket (A).
|
•
|
Do not reuse the gasket.
|
|
•
|
When removing the gasket, do not use sharp tools and be careful not to damage it.
|
|
|
| 6. |
Before replacing with a new inverter/body kit, apply thermal grease as shown in the picture below.
Quantity : Apply 5 g (compressor heat sink)
|
|
•
|
When replacing the inverter/body kit, be careful of static electricity and work in a clean
room [consistent temperature and humidity: 22°C (71.6°F) - 23°C (73.4°F), 50%].
|
|
•
|
General grease cannot be used, and the supplied thermal grease must be used.
|
|
•
|
When applying thermal grease, wipe off foreign substances in the grease with alcohol.
|
|
•
|
When applying grease on the grease application area (A), be careful not to let foreign
substances enter the 3-phase power pin (B).
|
|
•
|
When replacing the inverter or body kit, it is recommended to wipe off the existing thermal
grease and apply the supplied thermal grease.
|
|
|
| 7. |
Install the new gasket and install the inverter kit (A) into the body kit, taking care not to damage the
3-phase power pin.
|
•
|
When installing the inverter kit and body kit, be careful about breakage and
distortion/bending of the 3-phase power pin.
|
|
•
|
Inverter kit and body kit gaskets are not to be reused.
|
|
|
| 8. |
Assemble the inverter kit and body kit by tightening the new bolts (A).
Tightening torque :
11.8 - 12.7 N·m (1.2 - 1.3 kgf·m, 8.7 - 9.4 lb·ft)
|
|
•
|
When installing the inverter kit and body kit, be careful as the internal PCB of the
inverter/body kit may be bent due to vehicle vibration when installed with over-torque or
under-torque.
|
|
•
|
Do not reuse the inverter kit and body kit tightening bolts.
|
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Reassemble in the reverse order of disassembly.
|
Evaporator Temperature Sensor Description and Operation
|
•
|
The temperature of the evaporator core is sensed and converted into a resistance value. It is a negative
temperature coefficient (NTC) thermistor type in which the resistance value decreases when the temperature
rises and the resistance value increases when the temperature decreases.
|
|
•
|
Prevents freezing of the evaporator core when using the air conditioner for a long time.
|
|
–
|
When the temperature of the evaporator core is below about 0.5 - 1.5 °C, the air conditioner relay output
power is cut off to stop the operation of the compressor.
|
|
–
|
When the temperature of the evaporator core reaches about 3 - 4 °C, the air conditioner relay operates to
operate the compressor.
|
Evaporator Temperature Sensor Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Remove the evaporator core.
(Refer to Heater - "Evaporator Core")
|
| 2. |
Remove the evaporator temperature sensor (A).
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Evaporator Temperature Sensor Inspection. In-car Sensor Description and Operation
Evaporator Temperature Sensor Inspection
| 2. |
Turn on the air conditioner switch.
|
| 3. |
Measure the resistance of the ( + ) and ( - ) terminals after connecting the multi-tester to the evaporator
temperature sensor.
1. Sensor Ground
|
2. Evaporator Sensor ( + )
|
Temperature [°C (°F)]
|
Resistance (kΩ)
|
-10 (14)
|
17.67 - 18.19
|
0 (32)
|
11.25 - 11.47
|
10 (50)
|
7.292 - 7.5
|
20 (68)
|
4.847 - 5.025
|
30 (86)
|
3.296 - 3.443
|
40 (104)
|
2.289 - 2.408
|
|
In-car Sensor Description and Operation
|
•
|
The in-car sensor detects the indoor temperature and is used for discharge temperature control, sensor
compensation, mix door control, blower motor speed control, air conditioner auto control, and heating start
control.
|
|
•
|
When the temperature is sensed by sucking in the indoor air and the resistance value is changed, the
corresponding voltage value is transmitted to the automatic temperature control module.
|
In-car Sensor Removal and Installation
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "High Voltage
System General Safety Information and Caution". If not, it may cause serious accidents such as
electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
| 1. |
Remove the crash pad center garnish [RH].
(Refer to Body - "Crash Pad Garnish")
|
| 2. |
Remove the in-car sensor (A) after removing the screws.
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Inner Condenser Removal and Installation
| 1. |
Remove the heater unit.
(Refer to Heater - "Heater Unit")
|
| 2. |
Remove the inner condenser cover.
| (1)
|
Separate the evaporator temperature sensor (A).
|
| (2)
|
Remove the inner condenser cover (B) after removing the screws.
|
|
| 3. |
Remove the inner condenser (A) in the direction of the arrow.
|
| 1. |
Install in the reverse order of removal.
|
•
|
If a new condenser is installed, replenish the compressor oil (POE OIL).
|
|
•
|
Replace the O-rings at each connection with new ones, and apply a few drops of compressor
oil (refrigerant oil) to the O-rings before connecting hoses or lines. To avoid leakage of
R-1234yf, use the specified O-ring.
|
|
•
|
When installing the condenser, be careful not to have an impact on the condenser pin.
|
|
•
|
Charge the refrigerant system and test the air conditioner performance.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
|
Photo Sensor Description and Operation
The photo sensor (daylight sensor) is located above the sensor speaker grill. It has a built-in photovoltaic diode
(sensing solar radiation). Luminescence appears in the part where light is received, and electric force is generated
in proportion to the amount of light emission, and this electric force is transmitted to the automatic temperature
control module to compensate for air volume and discharge temperature.
Photo Sensor Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Remove the center speaker grille.
(Refer to Body - "Crash Pad Cover")
|
| 2. |
Remove the photo sensor (A) in the direction of the arrow by pressing the fixing hook.
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "General
Safety Information and Caution". If not, it may cause serious accidents such as electric shock or
short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Receiver-Drier Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
|
If the air conditioner is operational, run it for a few minutes.
|
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Remove the front under cover.
(Refer to Motor and Reduction Gear System - "Front Under
Cover")
|
| 3. |
Remove the receiver drier cap (A).
|
| 4. |
Remove the receiver drier filter (A) and O-ring (B).
|
| 5. |
Remove the desiccant (A).
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
•
|
Be sure to inject the specified refrigerant and refrigeration oil (POE) by using the
refrigerant recovery/charging equipment dedicated to the electric compressor.
|
|
•
|
Perform the refrigerant leak test/vacuum/charging by using the refrigerant
recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
•
|
Perform the compressor oil inspection.
(Refer to Air Conditioning System - "Compressor
Oil")
|
|
|
Refrigerant Line Removal and Installation - Non Heat Pump
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Suction & Liquid Tube Assembly
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Drain the coolant.
(Refer to Cooling System - "Coolant")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnect the chiller hoses (A).
|
| 5. |
Disconnect the expansion valve connector (A).
|
| 6. |
Disconnect the A/C transducer connector (A).
|
| 7. |
Separate the discharge hose assembly (A) after removing the nut.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 8. |
Separate the suction & liquid tube assembly (A) after removing the bolts and nuts.
[Inner Condenser]
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
[Evaporator Core]
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
[Chiller]
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
[Condenser]
Tightening torque :
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
[Water Condenser - 2WD]
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
[Water Condenser - 4WD]
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
[Compressor - 2WD]
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 9. |
Remove the suction & liquid tube assembly (A) after removing the bolt.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
Suction Hose 1
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 3. |
Disconnect the A/C transducer connector (A).
|
| 4. |
Remove the suction hose 1 (A) after removing the nut.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
| 5. |
Remove the suction hose 1 (A) after removing the bolt.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
Discharge Hose
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Remove the auxiliary 12 V battery tray.
(Refer to Battery Control System - "Auxiliary 12 V Battery Tray -
2WD")
(Refer to Battery Control System - "Auxiliary 12 V Battery Tray -
4WD")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnect the A/C transducer connector (A).
|
| 5. |
Separate the discharge hose (A) after removing the nut.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 6. |
Remove the discharge hose.
[2WD]
| (1)
|
Separate the discharge hose (A) from coolant distribution pipe after removing the nut.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| (2)
|
Separate the discharge hose (A) after removing the bolt.
Tightening torque :
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| (3)
|
Remove the discharge hose (A) after removing the bolt.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
[4WD]
| (1)
|
Remove the discharge hose bolt (A).
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
| (2)
|
Remove the discharge hose (A) after removing the bolt.
Tightening torque :
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in reverse order of removal.
|
•
|
Be sure to inject the specified refrigerant and refrigeration oil (POE) by using the
refrigerant recovery/charging equipment dedicated to the electric compressor.
|
|
•
|
Perform the refrigerant leak test/vacuum/charging by using the refrigerant
recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
•
|
Perform the compressor oil inspection.
(Refer to Air Conditioning System - "Compressor
Oil")
|
|
|
| 2. |
Refill the high voltage battery coolant.
(Refer to Electric Vehicle Cooling System - "Coolant")
|
Refrigerant Line Removal and Installation - Heat Pump
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Suction & Liquid Tube Assembly
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Drain the coolant.
(Refer to Cooling System - "Coolant")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnect the chiller hoses (A).
|
| 5. |
Disconnect the expansion valve connector (A).
|
| 6. |
Disconnect the 2-way valve connector (A).
|
| 7. |
Separate the discharge hose assembly (A) after removing the nut.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 8. |
Separate the suction & liquid tube assembly (A) after removing the bolts and nuts.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
[Inner Condenser]
[Evaporator Core]
[Chiller]
[Condenser]
[Water Condenser]
|
| 9. |
Remove the suction & liquid tube assembly (A) after removing the bolt.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
Suction Hose Assembly 1
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 3. |
Remove the suction hose assembly 1 (A) after removing the nuts.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
[2WD]
[4WD]
|
Suction Hose Assembly 2
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Remove the auxiliary 12 V battery tray.
(Refer to Battery Control System - "Auxiliary 12 V Battery Tray -
2WD")
(Refer to Battery Control System - "Auxiliary 12 V Battery Tray -
4WD")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnect the A/C pressure transducer connector (A)
[2WD]
[4WD]
|
| 5. |
Remove the suction hose assembly 2 (A) after removing the bolts and nuts.
Tightening torque :
Bolt : 21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
Nut : 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
[2WD]
[4WD]
|
Discharge Hose Assembly
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Remove the auxiliary 12 V battery tray.
(Refer to Battery Control System - "Auxiliary 12 V Battery Tray -
2WD")
(Refer to Battery Control System - "Auxiliary 12 V Battery Tray -
4WD")
|
| 3. |
Disconnect the A/C temperature transducer connector (A).
|
| 4. |
Remove the discharge hose.
[2WD]
| (1)
|
Separate the discharge hose (A) from coolant distribution pipe after removing the nut.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| (2)
|
Separate the discharge hose (A) after removing the bolt.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| (3)
|
Remove the discharge hose (A) after removing the bolt.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
[4WD]
| (1)
|
Remove the discharge hose bolt (A).
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| (2)
|
Remove the discharge hose (A) after removing the bolt.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
•
|
Be sure to inject the specified refrigerant and refrigeration oil (POE) by using the
refrigerant recovery/charging equipment dedicated to the electric compressor.
|
|
•
|
Perform the refrigerant leak test/vacuum/charging by using the refrigerant
recovery/recycling/charging machine.
(Refer to Air conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
|
|
| 2. |
Refill the high voltage battery coolant.
(Refer to Electric Vehicle Cooling System - "Coolant")
|
Water Condenser Removal and Installation - Non Heat Pump
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "High Voltage
System General Safety Information and Caution". If not, it may cause serious accidents such as
electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
| 1. |
Recover refrigerant by using the refrigerant recovery/recycling/charging machine.
(Refer to Air Conditioning System - "Refrigerant
Recovery/Recycling/Charging/Vacuum/Leak Test")
|
| 2. |
Drain the coolant.
(Refer to Cooling System - "Coolant")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnet the water condenser hoses (A).
|
| 5. |
Separate the suction & liquid tube assembly (A) after removing the nuts.
[2WD]
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
[4WD]
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 6. |
Remove the water condenser (A) after removing the bolts and nut.
Tightening torque
Bolt : 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
Nut : 8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
Installation
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "High Voltage
System General Safety Information and Caution". If not, it may cause serious accidents such as
electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
| 1. |
Install in reverse order of removal.
|
Be sure to inject the specified refrigerant (R-1234yf) and refrigeration oil (POE) by using the
refrigerant recovery/charging equipment dedicated to the electric compressor. Compressor damage and
safety accidents may occur if refrigeration oil (PAG) of general vehicles is mixed.
|
|
•
|
If a new condenser is installed, replenish the compressor oil (POE OIL).
|
|
•
|
Replace the O-rings at each connection with new ones, and apply a few drops of compressor
oil (refrigerant oil) to the O-rings before connecting hoses or lines. To avoid leakage of
R-1234yf, use the specified O-ring.
|
|
•
|
Charge the refrigerant system and test the air conditioner performance.
|
|
|
Water Condenser Removal and Installation - Heat Pump
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "High Voltage
System General Safety Information and Caution". If not, it may cause serious accidents such as
electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
| 1. |
Recover the refrigerant with recovery/recycling/charging equipment.
(Refer to Air Conditioning - "Refrigerant
Recovery/Recycling/Charging/Evacuation")
|
| 2. |
When the motor is cooled, the coolant is drained from the radiator.
(Refer to Cooling System - "Coolant")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnect the expansion valve connector (A).
|
| 5. |
Disconnect the 3-way valve connector (A).
|
| 6. |
Remove the water condenser wiring clip (A).
|
| 7. |
Separate the suction & liquid tube assembly (A) after removing the nuts.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 8. |
Separate the liquid hose after removing the nut (A).
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 9. |
Separate the suction hose 1 (A) after removing the nut.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
| 10. |
Disconnect the water condenser hose (A).
|
| 11. |
Remove the bolts (A) from the water condenser.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
| 12. |
Remove the water condenser (A) after removing the nut.
Tightening torque :
8.8 - 13.7 N·m (0.9 - 1.4 kgf·m, 6.5 - 10.1 lb·ft)
|
|
Installation
|
•
|
When working on high voltage system, the work should be performed by technicians who have completed
the relevant training. A lack of understanding of the high voltage system can lead to serious
accidents due to electric shock or electric leakage.
|
|
•
|
When working a high voltage system, the technician must be observed and aware of "High Voltage
System General Safety Information and Caution". If not, it may cause serious accidents such as
electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedures.
|
|
| 1. |
Install in reverse order of removal.
|
Be sure to inject the specified refrigerant (R-1234yf) and refrigeration oil (POE) by using the
refrigerant recovery/charging equipment dedicated to the electric compressor. Compressor damage and
safety accidents may occur if refrigeration oil (PAG) of general vehicles is mixed.
|
|
•
|
If a new condenser is installed, replenish the compressor oil (POE OIL).
|
|
•
|
Replace the O-rings at each connection with new ones, and apply a few drops of compressor
oil (refrigerant oil) to the O-rings before connecting hoses or lines. To avoid leakage of
R-1234yf, use the specified O-ring.
|
|
•
|
Charge the refrigerant system and test the air conditioner performance.
(Refer to Air Conditioning - "Refrigerant
Recovery/Recycling/Charging/Evacuation")
|
|
|
| 2. |
Refill with coolant.
(Refer to Cooling System - "Coolant")
|
Other information:
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: When flatbed is unavailable
A 2WD Kia EV6 may be towed without dollies only if the wheels not connected to the drive system remain on the
ground.
Release the parking brake before switching the vehicle OFF.
If towing the Kia EV6 using only two wheels, always lift the driven wheels completely off the ground.
CAUTION
If any loaded wheel, tire, or suspension component is damaged, or if the Kia EV6 must be towed with
the
driven wheels contacting the road surface, install towing dollies beneath the driven wheels.
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Charging door operation
Pull the Kia EV6 headrest fully forward and release it to adjust the forward position.
The adjustable Kia EV6 headrest design allows improved neck support and enhanced driving comfort during long
trips.
TIP
The Kia EV6 headrest can be adjusted forward into 3 different locking positions by repeatedly pulling the
headrest forward.