Kia EV6: Body (Interior / Exterior / Electrical) / Front Door
Contents:
Components and Components Location
| Component and Component Location |
Front Door [Trim]
1. Front Door Trim 2. Front Door Inside Handle 3.
Main Power Window Switch 4. Sub Power Window Switch 5. Front Door Belt Inside Weatherstrip
|
6. Front Door Belt Outside Weatherstrip 7. Front Door
Frame Molding 8. Front Door Frame Garnish 9. Front Door Body Side Weatherstrip 10. Front Door Side
Weatherstrip.
|
Front Door [Mechanism]
1. Front Door Module 1-a. 8.8 - 11.8 N·m (0.9 - 1.2
kgf·m, 6.5 - 8.7 lb·ft) 2. Front Door Latch 2-a. 6.9 - 10.8 N·m (0.7 - 1.1 kgf·m, 5.1 - 8.0 lb·ft) 3.
Front Door Speaker 4. Front Door Window Glass 4-a. 8.8 - 11.8 N·m (0.9 - 1.2 kgf·m, 6.5 - 8.7 lb·ft)
|
5. Front Door Glass Run 6. Front Door Latch 6-a.
6.9 - 10.8 N·m (0.7 - 1.1 kgf·m, 5.1 - 8 lb·ft) 7. Front Door Outside Handle 7-a. 3.4 - 5.7 N·m (0.35 -
0.58 kgf·m, 2.5 - 4.2 lb·ft, 30.4 - 50.3 lb·in)
|
Adjustment
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Door Adjustment
| 1. |
Check that the gap between the door and the body is even after parking in a flat level.

|
| 2. |
Loosen the door hinge (A) bolts (B), adjust the door (C) by moving it back and forth, left and right, and
then tighten the bolts.
Tightening torque :
21.6 - 26.5 N·m (2.2 - 2.7 kgf·m, 15.9 - 19.5 lb·ft)
|


|
| 3. |
Check that the gap between the door and the body is even.
|
Striker Adjustment
| 1. |
Loosen the screws (B) and adjust the striker (A) by moving it back and forth, left and right, and then
tighten the screws.
Tightening torque :
18.6 - 33.3 N·m (1.9 - 3.4 kgf·m, 13.7 - 24.6 lb·ft)
|

|
| 2. |
Check that the door opens and closes properly.
|
Glass Adjustment
|
Check the damage of the glass run and channel and replace them if necessary.
|
| 1. |
Remove the front door trim.
(Refer to Front Door - "Front Door Trim")
|
| 2. |
Adjust the gap by moving the window glass (A) up, down, left and right, and then tighten the bolts.
Tightening torque :
8.8 - 11.8 N·m (0.9 - 1.2 kgf·m, 6.5 - 8.7 lb·ft)
|

|
| 3. |
Check the window glass for normal operation.
|
Window Motor Reset
| 1. |
With the window open, use the auto/manual up switch to completely close the window and keep it closed for
more than 0.2 seconds.
(If you operate the up switch while the window is completely closed, it will not be initialized)
|
On Vehicle Inspection
| 1. |
The front door can quickly diagnosed for problems with the KDS. (Refer to "DTC guide")
| (1)
|
Self diagnosis : Inspect the Diagnostic Trouble Code (DTC) with the KDS.
(Refer to DTC guide when fault code is found.)
|
|
Refer to the KDS screen for operating conditions and details
|
|
Protection of Window Motor Overheating
| 1. |
The motor can continuously operate at least 15 strokes, and it can be operated again 30 to 40 seconds after
the motor stops due to the overheat protection function.
|
Front Door Garnish and Molding Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Door Frame Molding
| 1. |
Remove the molding (A).
|
Clip position :
|
|
Door Frame Garnish
| 1. |
Remove the garnish (A).
|
Clip position :
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Handle Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
Door Inside Handle
| 1. |
Remove the front door trim.
(Refer to Front Door - "Front Door Trim")
|
| 2. |
Remove the handle (A) after removing the screws.
|
Door Outside Handle
| 1. |
Remove the front door module.
(Refer to Front Door - "Front Door Module")
|
| 2. |
Remove the bolt (A).
Tightening torque :
8.8 - 11.8 N·m (0.9 - 1.2 kgf·m, 6.5 - 8.7 lb·ft)
|
|
| 3. |
Remove the door lock assembly (A) by pulling it in the direction of the arrow.
|
| 4. |
Disconnect the handle connector (A).
|
| 5. |
Separate the handle wiring (A).
|
Clip position :
|
|
| 6. |
Separate the latch rod (A).
|
Clip position :
|
|
| 7. |
Remove the handle (A) after removing the nuts.
Tightening torque :
3.4 - 5.7 N·m (0.35 - 0.58 kgf·m, 2.5 - 4.2 lb·ft)
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Latch Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Remove the front door module.
(Refer to Front Door - "Front Door Module")
|
| 2. |
Disconnect the outside handle connector (A).
|
| 3. |
Separate the outside handle wiring (A).
|
Clip position :
|
|
| 4. |
Remove the screws (A).
Tightening torque :
6.9 - 10.8 N·m (0.7 - 1.1 kgf·m, 5.1 - 8.0 lb·ft)
|
|
| 5. |
Remove the latch (B) after separating the latch rod (A).
|
Clip position :
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Latch Inspection
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Remove the front door latch.
(Refer to Front Door - "Front Door Latch")
|
| 2. |
Apply voltage to connector terminal and check that the door latch operates properly.

Location
|
Terminal
|
Driver
|
7, 8
|
Passenger
|
1, 2
|
|
Front Door Module Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Remove the front door window glass.
(Refer to Front Door - "Front Door Window Glass")
|
| 2. |
Disconnect the door main wiring connector (A).
|
| 3. |
Disconnect the outside mirror connector (A).
|
| 4. |
Separate the door module (A) after removing the bolts.
Tightening torque :
8.8 - 11.8 N·m (0.9 - 1.2 kgf·m, 6.5 - 8.7 lb·ft)
|
|
| 5. |
Remove the door module after disconnecting the wiring connectors (A).
|
| 6. |
Separate the wiring harness (A).
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Speaker Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Door Speaker
| 1. |
Remove the front door trim.
(Refer to Front Door - "Front Door Trim")
|
| 2. |
Separate the speaker connector (A).
|
| 3. |
Remove the speaker (A) after removing the bolts.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Switch Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Power Window Main Switch
| 1. |
Remove the front door trim. [Driver's side]
(Refer to Front Door - "Front Door Trim")
|
| 2. |
Remove the switch (A) by pulling the hook in the direction of the arrow.
|
Power Window Sub Switch
| 1. |
Remove the passenger's side front door trim.
(Refer to Front Door - "Front Door Trim")
|
| 2. |
Remove the switch (A) by pulling the hook in the direction of the arrow.
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Trim Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Turn the POWER OFF, separate the auxiliary battery (12 V) ( - ) terminal, and disconnect the high voltage
service interlock connector.
| (1)
|
Open the front trunk (A).
|
| (2)
|
Open the auxiliary 12 V battery service cover (A).
|
| (3)
|
Turn the POWER OFF, separate the auxiliary battery (12 V) ( - ) terminal (A).
Tightening torque :
7.8 - 9.8 N·m (0.8 - 1.0 kgf·m, 5.8 - 7.2 lb·ft)
|
|
| (4)
|
Disconnect the service interlock connector (A).
|
•
|
Wait more than 5 minutes for capacitor of the high voltage battery system to be
discharged completely.
|
|
•
|
When working on a vehicle during discharging the capacitor, it can cause an
electrical shock or injury, so follow the manual.
|
|
|
The service interlock connector cannot be completely removed.
|
|
|
| 2. |
Separate the quadrant inner cover (A).
|
| 3. |
Remove the quadrant inner cover (A) after disconnecting the tweeter speaker connector.
|
| 4. |
Separate the door trim (A) after removing the screw.
|
Clip position :
|
|
| 5. |
Remove the door trim after disconnecting the connectors (A).
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Weatherstrip Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
Door Side Weatherstrip
| 1. |
Separate the door checker (A) after removing the bolt.
Tightening torque :
21.6 - 32.4 N·m (2.2 - 3.3 kgf·m, 15.9 - 23.9 lb·ft)
|
|
| 2. |
Remove the weatherstrip (A).
|
Door Body Side Weatherstrip
| 1. |
Remove the weatherstrip (A).
|
Door Belt Outside Weatherstrip
| 1. |
Remove the weatherstrip (A).
|
Door Belt Inside Weatherstrip
| 1. |
Remove the front door trim.
(Refer to Front Door - "Front Door Trim")
|
| 2. |
Remove the weatherstrip (A).
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Window Glass Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Door Window Glass
| 1. |
Remove the front door belt inside and outside weatherstrips.
(Refer to Front Door - "Front Door Weatherstrip")
|
| 2. |
Lower it until window glass bolt is exposed in the hold plug by operating the power window switch.
|
| 3. |
remove the window glass (A) after removing the bolts.
Tightening torque :
8.8 - 11.8 N·m (0.9 - 1.2 kgf·m, 6.5 - 8.7 lb·ft)
|
|
Door Window Glass Run
| 1. |
Remove the door window glass.
|
| 2. |
Remove the front door frame garnish and molding.
(Refer to Front Door - "Front Door Frame Garnsih and
Moilding")
|
| 3. |
Remove the glass run (A).
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
Front Door Window Motor Removal and Installation
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
Power Window Motor
| 1. |
Remove the front door trim.
(Refer to Front Door - "Front Door Trim")
|
| 2. |
Remove the motor connector (A).
|
| 3. |
Remove the motor (A) after removing the bolts.
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|
|
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on the high voltage system, make sure to check the Personal Protective Equipment (PPE)
and high voltage shut-off procedure.
|
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the window motor reset procedure.
(Refer to Front Door - "Adjustment")
|