Contents:
| Special Service Tool |
|
Tool Name / Number |
Illustration |
Description |
|
Coolant refiller & suction tool 0K253 - J2300 |
|
Used to drain and fill the coolant for EV |
|
Cap adapter 0K253 - J2320 |
|
Used to drain and fill the coolant for EV |
| 1. Pressure Valve 2. Suction Valve 3. Vacuum Valve 1 4. Vacuum Valve 2 5. Coolant Injection 6. Vacuum Valve 7. Regulator Pressure Gauge |
8. Pressure Gauge 9. Vacuum Gauge 10. Air Pressurization Valve 11. Vacuum Outlet Valve 12. Air Hose Inlet Valve 13. Regulator Adjusting Knob |
| Drain |
|
| 1. |
Disconnect the battery negative ( - ) terminal and the high voltage service interlock connector.
(Refer to Battery Control System - "Auxiliary Battery (12
V)")
(Refer to Battery Control System - "Auxiliary Battery (12 V)"
-4WD)
|
| 2. |
Open the reservoir tank cap (A).
|
| 3. |
Install the cap adapter (0K253 - J2320).
|
| 4. |
Install the radiator cap connection hose (A) to the radiator cap adapter (B).
|
| 5. |
Connect the radiator cap connection hose (A) to the air pressurization valve of SST (0K253 - J2300).
|
| 6. |
Install the air hose (A) to the air inlet valve of SST (0K253 - J2300).
|
| 7. |
Turn the regulator adjusting knob (A) to set pressure gauge (B) to 0.2 Mpa.
|
| 8. |
Remove the front under cover.
(Refer to Motor & Reduction Gear System - "Front Under
Cover")
|
| 9. |
Release the quick connector, and then disconnect the high voltage battery EWP cooling hose (A).
[2WD]
[4WD]
|
| 10. |
Install the coolant drain adapter and hose (A) to the battery EWP and EWP cooling hose.
[2WD]
[4WD]
|
| 11. |
Put the opposite of the coolant drain adapter and hose (A) to a bucket (B).
|
| 12. |
Turn the pressure valve (A) the direction of the arrow to drain coolant.
|
| 13. |
Close the pressure valve after draining coolant, and then install the high voltage battery EWP coolant hose
(A).
[2WD]
[4WD]
|
| 14. |
Separate the radiator cap connection hose (A) to the air pressurization valve.
|
| Special Service Tool |
|
Tool Name / Number |
Illustration |
Description |
|
Coolant refiller & suction tool 0K253 - J2300 |
|
Used to drain and fill the coolant for EV |
|
Cap adapter 0K253 - J2320 |
|
Used to drain and fill the coolant for EV |
| 1. Pressure Valve 2. Suction Valve 3. Vacuum Valve 1 4. Vacuum Valve 2 5. Coolant Injection 6. Vacuum Valve 7. Regulator Pressure Gauge |
8. Pressure Gauge 9. Vacuum Gauge 10. Air Pressurization Valve 11. Vacuum Outlet Valve 12. Air Hose Inlet Valve 13. Regulator Adjusting Knob |
| Refilling |
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Connect the radiator cap connection hose (A) to the vacuum valve of SST (0K253 - J2300).
|
| 3. |
Open the vacuum valve (A) in the direction of the arrow, and then close when the vacuum gauge (B) reaches
the green area (C).
|
| 4. |
Connect the coolant suction hose (A) to SST (0K253 - J2300) coolant filler valve and place the opposite
hose in the bucket (B) containing new coolant.
|
| 5. |
Turn the suction valve (A) in the direction of the arrow to fill new coolant, and then close it when the
vacuum gauge reaches to '0'.
|
| 6. |
Remove the cap adapter (0K253 - J2320).
|
| 7. |
Perform the order below with the KDS.
(Actuation Test → Vehicle Control → Battery EWP Operation Mode for Degassing and Circulation)
|
| 8. |
When the battery EWP operates and coolant circulates, refill coolant so that the coolant level is kept
between "MAX" and "MIN" level.
|
| 9. |
When the operational sound volume of the EWP becomes small and when no air bubbles can be seen in the
reservoir tank, bleeding of the coolant system is completed.
|
| 10. |
After air bleeding is completed, refill the coolant to the MAX level and install the reservoir cap.
|
| 11. |
Check the coolant for leakage.
|
| 12. |
Install the front under cover.
(Refer to Motor & Reduction Gear System - "Front Under
Cover")
|
| Component and Component Location |
| 1. Distribution Pipe Cooling Hose 2. Distribution Pipe Cooling Hose 3. Distribution Pipe Cooling Hose |
4. Coolant Distribution Pipe 4-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
| 1. Distribution Pipe Cooling Hose 2. Distribution Pipe Cooling Hose 3. Distribution Pipe Cooling Hose |
4. Coolant Distribution Pipe 4-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
| Removal |
|
When disconnecting a quick connector, refer to the following according to the type of quick connector.
[Type A]
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
[Type B]
- Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the
hose.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Disconnect the coolant distribution pipe cooling hose (A) by releasing the quick connector.
|
| 3. |
Disconnect the coolant distribution pipe cooling hoses (A, B, C) after releasing the quick connectors.
|
| 4. |
Disconnect the coolant distribution pipe cooling hose (A) by releasing the quick connector.
|
| 5. |
Remove the discharge hose (A) after removing the nut.
|
| 6. |
Remove the coolant distribution pipe (A) after removing the bolts.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
| Removal |
|
When disconnecting a quick connector, refer to the following according to the type of quick connector.
[Type A]
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
[Type B]
- Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the
hose.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 3. |
Disconnect the coolant distribution pipe cooling hose (A) by releasing the quick connector.
|
| 4. |
Disconnect the coolant distribution pipe cooling hoses (A) by releasing the quick connectors.
|
| 5. |
Disconnect the coolant distribution pipe cooling hose (A) by releasing the quick connector.
|
| 6. |
Disconnect the coolant distribution pipe cooling hose (B) by releasing the quick connector after
disconnecting the coolant temperature sensor (A).
|
| 7. |
Separate the motor and reduction gear oil cooler hose (A).
|
| 8. |
Remove the coolant distribution pipe (A) after removing the bolt and nut.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
| Specification |
| Item |
Specification |
|
|
Standard |
Long range |
|
|
Rated voltage (V) |
DC 523 |
DC 697 |
|
Input voltage (V) |
DC 360 - 619 |
DC 480 - 826 |
|
Heater capacity (kW) |
4.04 |
4.6 |
|
Ampere (A) |
Maximum 9.1 |
Maximum 7.8 |
|
Heater resistance (Ω) |
64.3 - 71.1 |
100.3 - 110.9 |
|
Operating temperature [°C (°F)] |
-40 to 105 (-40 to 221) |
-40 to 105 (-40 to 221) |
| Component and Component Location |
| 1. Battery Heater Coolant Hose 2. Battery Heater Coolant Hose |
3. Battery Heater 3-a. 6.9 - 9.8 N·m (0.7 - 1.0 kgf·m, 5.1 - 7.2 lb·ft) |
| 1. Battery Heater Coolant Hose 2. Battery Heater Coolant Hose |
3. Battery Heater 3-a. 6.9 - 9.8 N·m (0.7 - 1.0 kgf·m, 5.1 - 7.2 lb·ft) 3-b. 6.9 - 9.8 N·m (0.7 - 1.0 kgf·m, 5.1 - 7.2 lb·ft) |
| Inspection |
| 1. |
The cooling system can be more quickly diagnosed for problems using the KDS (Refer to "DTC
guide").
|
| Removal |
|
Follow the instructions below when releasing the quick connector.
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Perform the high voltage shut off procedure.
(Refer to Cooling System - "High Voltage Shut-off
Procedures")
|
| 2. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnect the battery heater connector (A).
|
| 5. |
Disconnect the battery heater coolant hose (A) after releasing the quick connector.
|
| 6. |
Separate the battery heater ground cable (A) after removing the bolt.
|
| 7. |
Disconnect the battery heater coolant hose (A) after releasing the quick connector.
|
| 8. |
Disconnect the battery heater high voltage connector (A).
|
| 9. |
Separate the battery heater high voltage connector (A).
|
| 10. |
Remove the battery heater (A) after removing the bolts.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
| Removal |
|
Follow the instructions below when releasing the quick connector.
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Perform the high voltage shut off procedure.
(Refer to Cooling System - "High Voltage Shut-off
Procedures")
|
| 2. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 3. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 4. |
Disconnect the battery heater high voltage connector (A) and wiring clip (B).
|
| 5. |
Disconnect the battery heater coolant hose (A) after releasing the quick connector.
|
| 6. |
Separate the battery heater ground cable (A) after removing the bolt.
|
| 7. |
Disconnect the battery heater coolant hose (A) after releasing the quick connector.
|
| 8. |
Disconnect the battery heater connector (A) and wiring clip (B).
|
| 9. |
Remove the battery heater (A) after removing the bolts and nut.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
| Specification |
|
Item |
Specification |
|
Operation voltage (V) |
9 - 16 |
|
Rated current (A) |
Maximum 1.3 |
|
Operating temperature [°C (°F)] |
-40 to 115 (-40 to 239) |
| Component and Component Location |
| 1. 3-Way Valve Cooling Hose 2. 3-Way Valve Cooling Hose 3. 3-Way Valve Cooling Hose 4. 3-Way Valve 4-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
5. 3-Way Valve Hose 6. 3-Way Valve Hose 7. Coolant 3-Way Valve 7-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
| 1. 3-Way Valve Inlet Hose 2. 3-Way Valve Outlet Hose 3. 3-Way Valve Outlet Hose 4. 3-Way Valve 4-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
5. 3-Way Valve Hose 6. 3-Way Valve Hose 7. Coolant 3-Way Valve 7-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
| Removal |
|
Follow the instructions below when releasing the quick connector.
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Disconnect the 3 way valve cooling hoses (A, B, C) by releasing the quick connectors.
|
| 3. |
Disconnect the 3-way valve connector (A).
|
| 4. |
Remove the 3-way valve (A) after removing the bolts.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
| Removal |
|
Follow the instructions below when releasing the quick connector.
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 3. |
Disconnect the 3-way valve cooling hose (A) after releasing the quick connector.
|
| 4. |
Disconnect the 3-way valve cooling hoses (A) after releasing the quick connectors.
|
| 5. |
Disconnect the 3-way valve connector (A).
|
| 6. |
Remove the 3-way valve (A) after removing the bolts.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
| Specification |
|
Item |
Specification |
|
Operation voltage (V) |
9 - 16 |
|
Rated current (A) |
Maximum 6.5 |
|
Operating temperature [°C (°F)] |
-40 to 135 (-40 to 275) |
| Component and Component Location |
When checking the sensor data in KDS, the numbering of EWP will be different between Parts catalog and KDS
data.
|
|||||||||||||||||
| [2WD] |
| 1. Battery Electric Water Pump (EWP) 1 1-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 2. Motor Electric Water Pump (EWP) 2-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 3. Reservoir Tank Bracket 3-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
4. Reservoir Tank 5. Electric Water Pump Hose 6. Coolant Distribution Pipe 7. Battery Electric Water Pump (EWP) 2 7-a. 6.9 - 9.8 N·m (0.7 - 1 kgf·m, 5.1 - 7.2 lb·ft) |
| [4WD] |
| 1. Battery Electric Water Pump (EWP) 1 1-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 2. Motor Electric Water Pump (EWP) 2-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 3. Reservoir Tank Bracket 3-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 4. Reservoir Tank |
5. Distribution Pipe 6. Electric Water Pump Hose 7. Battery Electric Water Pump (EWP) 2 Bracket 8. Battery Electric Water Pump (EWP) 2 8-a. 6.9 - 9.8 N·m (0.7 - 1.0 kgf·m, 5.1 - 7.2 lb·ft) 9. Battery Electric Water Pump (EWP) 2 Bracket 9-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
| Inspection |
| 1. |
The cooling system can be more quickly diagnosed for problems using the KDS (Refer to "DTC
guide").
|
| Removal |
|
When disconnecting a quick connector, refer to the following according to the type of quick connector.
[Type A]
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
[Type B]
- Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the
hose.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Disconnect the reservoir tank cooling hose (A) after releasing the quick connector.
|
| 3. |
Disconnect the high voltage battery EWP connector (A) and wiring clip (B).
|
| 4. |
Disconnect the high voltage battery EWP cooling hose (A) after releasing the quick connector.
|
| 5. |
Remove the high voltage battery EWP (A) after removing the bolts.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Disconnect the high voltage battery EWP cooling hoses (A) after releasing the quick connectors.
|
| 3. |
Remove the wiring clips (A).
|
| 4. |
Disconnect the high voltage battery EWP connector (A).
|
| 5. |
Remove the high voltage battery EWP (A) after removing the bolt and nut.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
| Removal |
|
When disconnecting a quick connector, refer to the following according to the type of quick connector.
[Type A]
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
[Type B]
- Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the
hose.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Disconnect the reservoir tank cooling hose (A) after releasing the quick connector.
|
| 3. |
Disconnect the high voltage battery EWP connector (A).
|
| 4. |
Disconnect the high voltage battery EWP cooling hose (A) after releasing the quick connector.
|
| 5. |
Remove the high voltage battery EWP (A) after removing the bolts.
|
| 1. |
Drain the high voltage battery coolant.
(Refer to High Voltage Battery Coolant - "Drain")
|
| 2. |
Disconnect the high voltage battery EWP cooling hoses (A) after releasing the quick connectors.
|
| 3. |
Disconnect the high voltage battery EWP connector (A) and wiring clip (B).
|
| 4. |
Remove the high voltage battery EWP (A) after removing the bolts.
|
| 5. |
Remove the high voltage battery EWP bracket.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to High Voltage Battery Coolant - "Refilling")
|
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Head-Up Display (HUD) : (if equipped)
The Kia EV6 Head-Up Display (HUD) is an advanced transparent projection system that displays important driving information directly onto the windshield within the driver’s field of vision. This technology allows the Kia EV6 driver to monitor critical driving information without taking attention away from the road ahead. The HUD system can display information from the instrument cluster, navigation system, and various driver assistance technologies in real time.Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Theft-alarm system
The theft-alarm system of the Kia EV6 is designed to help protect the vehicle against unauthorized access and potential theft attempts. This advanced security system monitors door, hood, and liftgate activity and activates warning functions if unauthorized entry is detected. The Kia EV6 theft-alarm system operates in three separate stages.