Kia EV6: Cooling System
Contents:
Single-Use Parts
Non-reusable parts (Single-Use Parts)
Workshop manual provides “Components and Components Location� which can be used to identify “Non-reusable parts�.
When repairing a vehicle, Non-reusable parts such as fasteners, gaskets, washers, clips and garnishes must be
replaced. Kia Non-reusable parts are designed to be installed only once.
Before working on a vehicle, check “Components and Components Location� to find the non-reusable parts in a
system.
※ Symbol of Non-reusable parts
Symbol
|
Meaning
|
|

|
Do not reuse the part. Replace with a new one.
|
※ Example of “Components and Components Location�

High Voltage Shut-off Procedures
High Voltage Shut-off Procedures
| High Voltage Shut-off Procedures |
|
•
|
When working on the high voltage system, the work should be performed by technicians who have
completed the relevant training. A lack of understanding of the high voltage system can lead to
serious accidents due to electric shock or short circuit.
|
|
•
|
When working on the high voltage system or related components, be sure to observe and be aware of
the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due
to electric shock or short circuit.
|
|
•
|
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and
high voltage shut-off procedure.
|
|
|
High Voltage Component : Battery System Assembly (BSA), motor assembly, inverter assembly, high voltage
junction box, power cable, etc.
|
| 1. |
Check the Battery Management Unit (BMU) weld flag with the KDS.
(Data Analysis → Battery Management System (BMS) → BMU Weld Flag)
|
Refer to the KDS screen for operating conditions and details.
|
|
| 2. |
Open the front trunk (A).

|
| 3. |
Open the low voltage (12 V) battery service cover (A).

|
| 4. |
Turn the POWER OFF, separate the low voltage (12 V) battery ( - ) terminal (A).
Tightening torque :
7.8 - 9.8 N·m (0.8 - 1.0 kgf·m, 5.8 - 7.2 lb·ft)
|

|
| 5. |
Disconnect the service interlock connector (A).

|
•
|
Wait more than 5 minutes for capacitor of the high voltage battery system to be discharged
completely.
|
|
•
|
When working on a vehicle during discharging the capacitor, it can cause an electrical
shock or injury, so follow the manual.
|
|
|
The service interlock connector cannot be completely removed.

|
|
| 6. |
Remove the front under cover.
(Refer to Motor and Reduction Gear System - "Front Under
Cover")
|
| 7. |
Remove the high voltage battery cover (A).
Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)
|

|
| 8. |
Disconnect the front high voltage junction box power cable (A).

|
How to disconnect the connector
| 1) |
Release the locking clip (A) by pulling it.
|
| 2) |
Disconnect the connector by pushing the lever (A) in the direction of the arrow while
pressing the locking clip (B).
|

|
|
| 9. |
Remove the center floor rear under cover.
(Refer to Motor and Reduction Gear System - "Rear Under
Cover")
|
| 10. |
Disconnect the Integrated Charge Control Unit (ICCU) connector (A).

|
How to disconnect the connector
| 1) |
Release the locking clip (A) by pulling it.
|
| 2) |
Disconnect the connector while pressing the locking clip (B).

|
|
|
| 11. |
Disconnect the rear high voltage junction box power cable (A).

|
How to disconnect the connector
| 1) |
Release the locking clip (A) by pulling it.
|
| 2) |
Disconnect the connector by pushing the lever (A) in the direction of the arrow while
pressing the locking clip (B).
|

|
|
| 12. |
Measure the voltage between the high voltage power connector and high voltage battery terminal to check
whether the high voltage is shut-off.
30 V or less : Normal cut off high voltage circuit
Above 30 V : Fault on high voltage circuit
|
| (1)
|
Measure the voltage between the high voltage power connector positive ( + ) terminal and negative (
- ) terminal.

|
| (2)
|
Measure the voltage between the high voltage battery positive ( + ) and negative ( - ) terminal.

|
| (3)
|
Measure the voltage between the high voltage battery positive ( + ) terminal and ground.

|
| (4)
|
Measure the voltage between the high voltage battery negative ( - ) terminal and ground.

|
| (5)
|
Measure the voltage between the rear high voltage battery positive ( + ) and negative ( - )
terminal.

|
| (6)
|
Measure the voltage between the rear high voltage battery positive ( + ) terminal and ground.

|
| (7)
|
Measure the voltage between the rear high voltage battery negative ( - ) terminal and ground.

|
| 1) |
Check for insulation breakdown via KDS and physical leakage current before working on EV.
|
| 2) |
Remove the main fuse if insulation breakdown or leakage current is suspected. (Remove the
main fuse even when DTC CODE ON such as PRA malfunction)
(Refer to High Voltage Battery Control System - "Main
Fuse")
※ If there is no insulation breakdown or leakage current and it is normal, work without
removing the main fuse.
|
|
|
Special Service Tools
Tool Name / Number
|
Illustration
|
Description
|
Coolant refiller & suction tool 0K253 - J2300
|

|
Used to drain and fill the coolant for EV
|
Cap adapter 0K253 - J2320
|

|
Used to drain and fill the coolant for EV
|
Flow Diagram
â– Heat Pump

HTR : High-Temperature Radiator
LTR : Low-Temperature Radiator
â– Non Heat Pump

HTR : High-Temperature Radiator
LTR : Low-Temperature Radiator
Other information:
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Limitations of Blind-Spot Collision-Avoidance Assist
The Kia EV6 Blind-Spot Collision-Avoidance Assist system may operate unexpectedly, become temporarily limited, or
fail to detect surrounding vehicles properly under certain road, weather, traffic, or environmental conditions.
Because the Kia EV6 Blind-Spot Collision-Avoidance Assist system relies on radar sensors and electronic detection
technology, detection performance can vary depending on surrounding obstacles, road geometry, weather, and
driving
behavior.
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: To operate
Pull and hold the left-side ( ) Kia EV6 paddle shifter while coasting.
When the Kia EV6 speed exceeds approximately 2 mph (3 km/h), the regenerative braking level returns to
the
previously selected setting after the paddle shifter is released.
When the Kia EV6 speed drops below approximately 2 mph (3 km/h), vehicle stopping control remains active
even
after the paddle shifter is released.