Contents:
| Special Service Tool |
|
Tool Name / Number |
Illustration |
Description |
|
Coolant refiller & suction tool 0K253 - J2300 |
|
Used to drain and fill the coolant for EV |
|
Cap adapter 0K253 - J2320 |
|
Used to drain and fill the coolant for EV |


| 1. Pressure Valve 2. Suction Valve 3. Vacuum Valve 1 4. Vacuum Valve 2 5. Coolant Injection 6. Vacuum Valve 7. Regulator Pressure Gauge |
8. Pressure Gauge 9. Vacuum Gauge 10. Air Pressurization Valve 11. Vacuum Outlet Valve 12. Air Hose Inlet Valve 13. Regulator Adjusting Knob |
| Drain |
|
| 1. |
Disconnect the battery negative ( - ) terminal and the high voltage service interlock connector.
(Refer to Battery Control System - "Auxiliary Battery (12
V)")
(Refer to Battery Control System - "Auxiliary Battery (12 V)"
-4WD)
|
| 2. |
Open the reservoir tank cap (A).
|
| 3. |
Install the cap adapter (0K253 - J2320).
|
| 4. |
Install the radiator cap connection hose (A) to the radiator cap adapter (B).
|
| 5. |
Connect the radiator cap connection hose (A) to the air pressurization valve of SST (0K253 - J2300).
|
| 6. |
Install the air hose (A) to the air inlet valve of SST (0K253 - J2300).
|
| 7. |
Turn the regulator adjusting knob (A) to set pressure gauge (B) to 0.2 Mpa.
|
| 8. |
Remove the rear under cover.
(Refer to Motor and Reduction Gear System - "Rear Under
Cover")
|
| 9. |
Disconnect the cooling hose (A) after releasing the quick connector.
|
| 10. |
Install the coolant drain adapter and hose (A) to the cooling hose.
|
| 11. |
Put the opposite of the coolant drain adapter and hose (A) to a bucket (B).
|
| 12. |
Turn the pressure valve (A) the direction of the arrow to drain coolant.
|
| 13. |
Close the pressure valve after draining coolant, and then install the cooling hose (A).
|
| 14. |
Separate the radiator cap connection hose (A) to the air pressurization valve.
|
| Special Service Tool |
|
Tool Name / Number |
Illustration |
Description |
|
Coolant refiller & suction tool 0K253 - J2300 |
|
Used to drain and fill the coolant for EV |
|
Cap adapter 0K253 - J2320 |
|
Used to drain and fill the coolant for EV |


| 1. Pressure Valve 2. Suction Valve 3. Vacuum Valve 1 4. Vacuum Valve 2 5. Coolant Injection 6. Vacuum Valve 7. Regulator Pressure Gauge |
8. Pressure Gauge 9. Vacuum Gauge 10. Air Pressurization Valve 11. Vacuum Outlet Valve 12. Air Hose Inlet Valve 13. Regulator Adjusting Knob |
| Refilling |
|
| 1. |
Drain the motor coolant.
(Refer to Motor Coolant - "Drain")
|
| 2. |
Connect the radiator cap connection hose (A) to the vacuum valve of SST (0K253 - J2300).
|
| 3. |
Open the vacuum valve (A) in the direction of the arrow, and then close when the vacuum gauge (B) reaches
the green area (C).
|
| 4. |
Connect the coolant suction hose (A) to SST (0K253 - J2300) coolant filler valve and place the opposite
hose in the bucket (B) containing new coolant.
|
| 5. |
Turn the suction valve (A) in the direction of the arrow to fill new coolant, and then close it when the
vacuum gauge reaches to '0'.
|
| 6. |
Remove the cap adapter (0K253 - J2320).
|
| 7. |
Perform the order below with the KDS.
(S/W Management → Vehicle Control → Electric Water Pump Control)
|
| 8. |
When the EWP operates and coolant circulates, refill coolant so that the coolant level is kept between
"MAX" and "MIN" level.
|
| 9. |
When the operational sound volume of the EWP becomes small and when no air bubbles can be seen in the
reservoir tank, bleeding of the coolant system is completed.
|
| 10. |
Install the rear under cover.
(Refer to Motor and Reduction Gear System - "Rear Under
Cover")
|
| Component and Component Location |
| 1. Motor and Reduction Gear Oil Cooler Cooling
Hose 2. Motor and Reduction Gear Oil Cooler Cooling Hose 3. Motor and Reduction Gear Oil Cooler Hose |
4. Motor and Reduction Gear Oil Cooler Hose 5. Front Motor and Reduction Gear Oil Cooler 5-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
| 1. Motor and Reduction Gear Oil Cooler Cooling
Hose 2. Motor and Reduction Gear Oil Cooler Cooling Hose 3. Motor and Reduction Gear Oil Cooler Hose |
4. Motor and Reduction Gear Oil Cooler Hose 5. Rear Motor and Reduction Gear Oil Cooler 5-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
| Removal |
|
Follow the instructions below when releasing the quick connector.
- Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the
hose.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the motor coolant.
(Refer to Motor Coolant - "Drain")
|
| 2. |
Remove the front under cover.
(Refer to Motor & Reduction Gear System - "Front Under
Cover")
|
| 3. |
Drain the front motor and reduction gear oil.
(Refer to Motor and Reduction Gear System - "Front Motor and Reduction
Gear Oil")
|
| 4. |
Disconnect the motor and reduction gear oil cooler cooling hoses (A) after releasing the quick connectors.
|
| 5. |
Separate the motor and reduction gear oil cooler hoses (A) after releasing the clamps.
|
| 6. |
Remove the motor and reduction gear oil cooler (A) after removing the bolts and nut.
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Refill the front motor and reduction gear oil.
(Refer to Motor and Reduction Gear System - "Front Motor and Reduction
Gear Oil")
|
| 3. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to Motor Coolant - "Refilling")
|
| Removal |
|
When disconnecting a quick connector, refer to the following according to the type of quick connector.
[Type A]
- Remove while pressing the quick connector clamp (A) in the direction of the arrow.
- Do not touch the rubber seal (A) inside the hose.
[Type B]
- Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the
hose.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the motor coolant.
(Refer to Motor Coolant - "Drain")
|
| 2. |
Remove the rear under cover.
(Refer to Motor and Reduction Gear System - "Rear Under
Cover")
|
| 3. |
Drain the rear motor and reduction gear oil.
(Refer to Motor and Reduction Gear System - "Rear Motor and Reduction
Gear Oil")
|
| 4. |
Separate the motor and reduction gear oil cooler hoses (A) after releasing the clamps.
|
| 5. |
Disconnect the motor and reduction gear oil cooler cooling hoses (A) after releasing the quick connectors.
|
| 6. |
Remove the motor and reduction gear oil cooler (A) after removing the bolts and nut.
|
| Installation |
| 1. |
Install in the reverse order of removal.
|
| 2. |
Refill the rear motor and reduction gear oil.
(Refer to Motor and Reduction Gear System - "Rear Motor and Reduction
Gear Oil")
|
| 3. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to Motor Coolant - "Refilling")
|
| Specification |
|
Item |
Specification |
|
Operation voltage (V) |
9 - 16 |
|
Rated current (A) |
Maximum 1.2 |
|
Operating temperature [°C (°F)] |
-40 to 90 (-40 to 194) |
| Component and Component Location |
| 1. 3-Way Valve Cooling Hose 2. 3-Way Valve Cooling Hose 3. 3-Way Valve Cooling Hose 4. 3-Way Valve 4-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
5. 3-Way Valve Hose 6. 3-Way Valve Hose 7. Coolant 3-Way Valve 7-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
| 1. 3-Way Valve Inlet Hose 2. 3-Way Valve Outlet Hose 3. 3-Way Valve Outlet Hose 4. 3-Way Valve 4-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
5. 3-Way Valve Hose 6. 3-Way Valve Hose 7. Coolant 3-Way Valve 7-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
| Description and Operation |

| Removal |
|
|
| 1. |
Disconnect the battery negative ( - ) terminal and the service interlock connector.
(Refer to Battery Control System - "Auxiliary 12 V
Battery")
|
| 2. |
Remove the front trunk.
(Refer to Body - "Front Trunk")
|
| 3. |
Open the reservoir tank pressure cap (A).
|
| 4. |
Use a suction device to drain the motor coolant (A) from the reservoir tank.
|
| 5. |
Disconnect the cooling hose (A) after releasing the quick connector.
|
| 6. |
Remove the bolts, and then remove the coolant 3way valve (A).
|
| 7. |
Disconnect the 3-way valve connector (B), and remove the 3way valve (A).
|
| Installation |
|
| 1. |
Install in the reverse order of removal.
|
| 2. |
Fill the coolant to the "MAX" line.
|
| 3. |
Perform the procedure below with the KDS.
(S/W Management → Vehicle Control → Electric Water Pump Control)
|
| 4. |
When the EWP operates and coolant circulates, fill coolant so that the coolant level is kept between
"MAX" and "MIN" level.
|
| 5. |
When the operating volume of the EWP becomes small and when no air bubbles can be seen in the reservoir
tank, bleeding of the coolant system is completed.
|
| 6. |
Close the reservoir tank pressure cap (A).
|
| Specification |
|
Item |
Specification |
|
Operation voltage (V) |
9 - 16 |
|
Rated current (A) |
Maximum 10 |
|
Operating temperature [°C (°F)] |
-40 to 135 (-40 to 275) |
| Component and Component Location |
When checking the sensor data in KDS, the numbering of EWP will be different between Parts catalog and KDS
data.
|
|||||||||||||||||
| [2WD] |
| 1. Battery Electric Water Pump (EWP) 1 1-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 2. Motor Electric Water Pump (EWP) 2-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 3. Reservoir Tank Bracket 3-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) |
4. Reservoir Tank 5. Electric Water Pump Hose 6. Coolant Distribution Pipe 7. Battery Electric Water Pump (EWP) 2 7-a. 6.9 - 9.8 N·m (0.7 - 1 kgf·m, 5.1 - 7.2 lb·ft) |
| [4WD] |
| 1. Battery Electric Water Pump (EWP) 1 1-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 2. Motor Electric Water Pump (EWP) 2-a. 2.0 - 2.5 N·m (0.20 - 0.25 kgf·m, 1.4 - 1.8 lb·ft, 17.4 - 21.7 lb·in) 3. Reservoir Tank Bracket 3-a. 7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft) 4. Reservoir Tank |
5. Coolant Distribution Pipe 6. Electronic Water Pump Hose 7. Battery Electric Water Pump (EWP) 2 Bracket 8. Battery Electric Water Pump (EWP) 2 8-a. 6.9 - 9.8 N·m (0.7 - 1.0 kgf·m, 5.1 - 7.2 lb·ft) 9. Battery Electric Water Pump (EWP) 2 Bracket 9-a. 19.6 - 23.5 N·m (2.0 - 2.4 kgf·m, 14.5 - 17.4 lb·ft) |
| Inspection |
| 1. |
The cooling system can be more quickly diagnosed for problems using the KDS (Refer to "DTC
guide").
|
| Removal |
|
When disconnecting a quick connector, refer to the following according to the type of quick connector.
- Pull the quick connector clamp (A) in the direction of the arrow to separate the clamp and remove the
hose.
- Do not touch the rubber seal (A) inside the hose.
|
| 1. |
Drain the motor coolant.
(Refer to Motor Coolant - "Drain")
|
| 2. |
Remove the 3 way valve.
(Refer to 3-Way Valve - "Removal and Installation")
|
| 3. |
Disconnect the motor EWP connector (A).
|
| 4. |
Disconnect the motor EWP cooling hose (A) after releasing the quick connector.
|
| 5. |
Remove the motor EWP (A) after removing the bolts.
|
| Installation |
| 1. |
Install in the reverse order of removal.
|
| 2. |
Perform the air bleeding procedures using the KDS after refilling the coolant.
(Refer to Motor Coolant - "Refilling")
|
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Brake bleeding
Special Service Tool Tool Name / Number Illustration Description Air bleeding tool0K580 - 3D100 Used for brake bleeding (regulating pressure)(Used with 0K585 - E8100) Air bleeding tool adaptor0K585 - E8100 Used for brake bleeding (reservoir cap adapter)(Used with 0K580 - 3D100) Integrated Electronic Brake (IEB) System Air Bleeding procedures • Do not reuse the drained brake fluid.Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Charging and climate
Tap the corresponding icon on the Kia EV6 infotainment screen to access Scheduled Charging and Target Temperature settings. NOTE To use scheduled charging features, the Kia EV6 must remain connected to a charging cable at the scheduled charging time. You can configure charging schedules, charging dates, charging times, and target cabin climate temperatures.