Kia EV6: Maintenance

Contents:

Single-Use Parts

Single-Use Parts
Non-reusable parts (Single-Use Parts)
Workshop manual provides “Components and Components Location� which can be used to identify “Non-reusable parts�. When repairing a vehicle, Non-reusable parts such as fasteners, gaskets, washers, clips and garnishes must be replaced. Kia Non-reusable parts are designed to be installed only once.
Before working on a vehicle, check “Components and Components Location� to find the non-reusable parts in a system.
※ Symbol of Non-reusable parts
Symbol
Meaning

Maintenance — Single-Use Parts illustration

Do not reuse the part. Replace with a new one.

※ Example of “Components and Components Location�

Maintenance — Single-Use Parts illustration

High Voltage System General Safety Information and Caution ➤

High Voltage Shut-off Procedures

High Voltage Shut-off Procedures

High Voltage Shut-off Procedures
Warning
•
When working on the high voltage system, the work should be performed by technicians who have completed the relevant training. A lack of understanding of the high voltage system can lead to serious accidents due to electric shock or short circuit.
•
When working on the high voltage system or related components, be sure to observe and be aware of the "Safety Precautions, Cautions and Warnings". If not, it may cause serious accidents due to electric shock or short circuit.
•
When working on high voltage system, make sure to check the Personal Protective Equipment (PPE) and high voltage shut-off procedure.
Information
High Voltage Component : Battery System Assembly (BSA), motor assembly, inverter assembly, high voltage junction box, power cable, etc.
1.
Check the Battery Management Unit (BMU) weld flag with the KDS.
(Data Analysis → Battery Management System (BMS) → BMU Weld Flag)

Specified value : NO

Information
Refer to the KDS screen for operating conditions and details.
2.
Open the front trunk (A).

Maintenance — High Voltage Shut-off Procedures illustration

3.
Open the low voltage (12 V) battery service cover (A).

Maintenance — High Voltage Shut-off Procedures illustration

4.
Turn the POWER OFF, separate the low voltage (12 V) battery ( - ) terminal (A).

Tightening torque :
7.8 - 9.8 N·m (0.8 - 1.0 kgf·m, 5.8 - 7.2 lb·ft)

Maintenance — High Voltage Shut-off Procedures illustration

5.
Disconnect the service interlock connector (A).

Maintenance — High Voltage Shut-off Procedures illustration

Warning
•
Wait more than 5 minutes for capacitor of the high voltage battery system to be discharged completely.
•
When working on a vehicle during discharging the capacitor, it can cause an electrical shock or injury, so follow the manual.
Note
The service interlock connector cannot be completely removed.

Maintenance — High Voltage Shut-off Procedures illustration

6.
Remove the front under cover.
(Refer to Motor and Reduction Gear System - "Front Under Cover")
7.
Remove the high voltage battery cover (A).

Tightening torque :
7.8 - 11.8 N·m (0.8 - 1.2 kgf·m, 5.8 - 8.7 lb·ft)

Maintenance — High Voltage Shut-off Procedures illustration

8.
Disconnect the front high voltage junction box power cable (A).

Maintenance — High Voltage Shut-off Procedures illustration

Note
How to disconnect the connector
1)
Release the locking clip (A) by pulling it.
2)
Disconnect the connector by pushing the lever (A) in the direction of the arrow while pressing the locking clip (B).

Maintenance — High Voltage Shut-off Procedures illustration

9.
Remove the center floor rear under cover.
(Refer to Motor and Reduction Gear System - "Rear Under Cover")
10.
Disconnect the Integrated Charge Control Unit (ICCU) connector (A).

Maintenance — High Voltage Shut-off Procedures illustration

Note
How to disconnect the connector
1)
Release the locking clip (A) by pulling it.
2)
Disconnect the connector while pressing the locking clip (B).

Maintenance — High Voltage Shut-off Procedures illustration

11.
Disconnect the rear high voltage junction box power cable (A).

Maintenance — High Voltage Shut-off Procedures illustration

Note
How to disconnect the connector
1)
Release the locking clip (A) by pulling it.
2)
Disconnect the connector by pushing the lever (A) in the direction of the arrow while pressing the locking clip (B).

Maintenance — High Voltage Shut-off Procedures illustration

12.
Measure the voltage between the high voltage power connector and high voltage battery terminal to check whether the high voltage is shut-off.

30 V or less : Normal cut off high voltage circuit
Above 30 V : Fault on high voltage circuit

(1)
Measure the voltage between the high voltage power connector positive ( + ) terminal and negative ( - ) terminal.

Maintenance — High Voltage Shut-off Procedures illustration

(2)
Measure the voltage between the high voltage battery positive ( + ) and negative ( - ) terminal.

Maintenance — High Voltage Shut-off Procedures illustration

(3)
Measure the voltage between the high voltage battery positive ( + ) terminal and ground.

Maintenance — High Voltage Shut-off Procedures illustration

(4)
Measure the voltage between the high voltage battery negative ( - ) terminal and ground.

Maintenance — High Voltage Shut-off Procedures illustration

(5)
Measure the voltage between the rear high voltage battery positive ( + ) and negative ( - ) terminal.

Maintenance — High Voltage Shut-off Procedures illustration

(6)
Measure the voltage between the rear high voltage battery positive ( + ) terminal and ground.

Maintenance — High Voltage Shut-off Procedures illustration

(7)
Measure the voltage between the rear high voltage battery negative ( - ) terminal and ground.

Maintenance — High Voltage Shut-off Procedures illustration

Warning
1)
Check for insulation breakdown via KDS and physical leakage current before working on EV.
2)
Remove the main fuse if insulation breakdown or leakage current is suspected. (Remove the main fuse even when DTC CODE ON such as PRA malfunction)
(Refer to High Voltage Battery Control System - "Main Fuse")
※ If there is no insulation breakdown or leakage current and it is normal, work without removing the main fuse.

Power Train ➤

Chassis ➤

Body ➤

Maintenance Schedule

Maintenance Schedule

Notice
For maintenance schedule refer to Owner's Manual Maintenance section.

Other information:

Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Brake disc cleaning

If surface rust develops on the brake discs or brake squeal becomes noticeable, the Kia EV6 includes a BDC (Brake Disc Cleaning) function designed to help reduce noise and remove rust buildup from the brake components. While the BDC function is active, regenerative braking is temporarily disabled and overall energy efficiency may decrease slightly.

Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: A Guide to Storage, Transport and Disposal of Old Battery Systems

Used high voltage battery system storage, transportation, disposal guide • When working on the high voltage system, the work should be performed by technicians who have completed the relevant training.

Contents