Contents:
| Air conditioner inspection and refrigerant charging |
| 1. |
Connect the R-1234yf recovery/recycling/charging equipment to the high-pressure service port (A) and
low-pressure service port (B) by reading the refrigerant recovery/recycling/charging equipment instruction
manual.
|
| 1. |
With the high and low pressure valves open, the refrigerant is recovered by using R-1234yf
recovery/recycling/charging equipment.
|
| 2. |
Measure the amount of compressor oil drained from the air conditioner system after the recovery operation
is completed. Supplement the compressor oil drained when charging the air conditioner refrigerant.
|
When charging the refrigerant, the air conditioner system must be evacuated. This evacuating operation is
performed to remove all the air and moisture that have flowed into the unit, and the system vacuums for more
than 10 minutes after each part is installed.
|
| 1. |
Perform the vacuum by using R-1234yf recovery/recycling/charging equipment while the high and low pressure
valves open.
|
| 2. |
If the gauge remains in the vacuum zone for 10 minutes while the high and low pressure valves closed,
vacuum has been performed normally. If the pressure increases, it is a leak in the system, so repair the leak
by the following order.
|
| 3. |
Make vacuum state by performing the refrigerant Recovery/Recycling/Charging equipment for more than 10
minutes, then close the high and low valves.
|
| 1. |
Replenish the amount of discharged compressor oil by using R-1234yf recovery/recycling/charging equipment
while the high pressure valve is opened after evacuating the air conditioner system.
|
| 2. |
Charge the refrigerant with specified amount while the high-pressure valve open by using the R-1234yf
recovery/recycling/charging equipment and then close the high-pressure valve.
|
| 3. |
Check that the refrigerant is not leaking from the system with leak detector. (Refer to refrigerant leak
test)
|
| 1. |
Check the torque of the connection part, and if it is too loose, check the gas leak with leak detector
after tightening it with the tightening torque.
|
| 2. |
If leakage continues even after re-tightening the connection part, drain the refrigerant and separate the
connection part to check the contact surface for damage. If there is even a small damage, replace it with a
new one.
|
| 3. |
Check the compressor oil and add oil if necessary.
|
| 4. |
Charging the system and check for gas leakage. If there is no problem, evacuate the system before charging.
|
| Replacement |
| 1. |
Open the front trunk (A).
|
| 2. |
Remove the service cover (A).
|
| 3. |
Remove the air filter cover (A) for air conditioner by pressing the filter cover knob in the direction of
the arrow.
|
| 4. |
Replace the air conditioner air filter (A).
|
| 5. |
Install in reverse order of removal.
|
| 1. |
Open the front trunk (A).
|
| 2. |
Remove the service cover (A).
|
| 3. |
Remove the air filter cover (A) for air conditioner by pressing the filter cover knob in the direction of
the arrow.
|
| 4. |
Replace the air conditioner air filter (A).
|
| 5. |
Install in reverse order of removal.
|
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Windows
The Kia EV6 is equipped with advanced power windows that can be conveniently operated using dedicated control switches located on each door panel. Power window lock button Rear door (left) power window switch Rear door (right) power window switch Driver’s door power window switch Front passenger’s door power window switch NOTE In freezing or wet weather conditions, the Kia EV6 power windows may operate slower than normal or temporarily stop functioning because of ice accumulation.Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Smart Key System Description and Operation
Description Main Features of The Smart Systems 1. Vehicle entry and control through driver and passenger doors and tailgate. 2. Detecting the presence or absence of a smart key indoor for starting the EV. 3.