Contents:
| Service Data |
| Electric Power Conversion System |
|
Item |
Specification |
|
Type |
eAGM60L-DIN |
|
Capacity [20HR/5HR] (AH) |
60 / 48 |
|
Cold cranking amperage (A) |
500 |
|
Reserve capacity (Min) |
100 |
|
Specific gravity |
1.30 - 1.32 [25°C (77°F)] |
|
Voltage (V) |
12 |
|
Item |
Specification |
|
Rated voltage (V) |
12 - 14 |
|
Operating voltage (V) |
6 - 18 |
|
Operating temperature [°C (°F)] |
-40 to 105 (-40 to 221) |
|
Parasitic current (uA) |
Maximum 300 |
|
Item |
Specification |
|
Input voltage (V) |
452.5 - 778.3 |
|
Operating voltage (V) |
9 - 16 |
|
Continuous current (A) |
75 (@20 min.) |
|
Maximum Ampere (A) |
190 (@15 sec.) |
|
Item |
Specification |
|
Input voltage (V) |
452.5 - 778.3 |
|
Operating voltage (V) |
9 - 16 |
|
Continuous current (A) |
180 (@20 min.) |
|
Maximum Ampere (A) |
245 (@15 sec.) |
| High Voltage Battery Control System |
| Item |
Specification |
|
| Operating voltage (V) |
9 - 16 |
|
| Operating temperature [°C (°F)] |
-35 to 75 (-31 to 167) |
|
| Insulated resistance (MΩ) |
10 (at 2 kV) |
|
| Parasitic current |
low voltage(mA) |
1 or below |
|
voltage(uA) |
100 or below |
|
|
Item |
Specification |
|
Operating voltage (V) |
9 - 65 (14 cells) |
|
Operating temperature [°C (°F)] |
-35 to 75 (-31 to 167) |
|
Insulated resistance (MΩ) |
10 (at 2 kV) |
|
Item |
Specification |
|
Resistance (Ω) |
1.0 or below [20°C (68°F)] |
| Power Relay Assembly (PRA) |
|
High Current (A) |
Output Voltage (V) |
|
- 750 (Charge) |
0.5 |
|
0 |
2.5 |
|
750 (Discharge) |
4.5 |
|
Low Current (A) |
Output Voltage (V) |
|
-75 |
0.5 |
|
0 |
2.5 |
|
75 |
4.5 |
|
Item |
Specification |
|
Rated voltage (V) |
12 |
|
Operating voltage (V) |
Maximum 9 |
|
Coil resistance (Ω) |
21.6 - 26.4 [20°C (68°F)] |
|
Item |
Specification |
|
Type |
Electronic relay |
|
Rated voltage (V) |
1,000 |
|
Rated current (A) |
20 |
| Temperature |
Resistance Value (kΩ) |
Tolerance (%) |
|
|
°C |
°F |
||
|
-40 |
-40 |
214.8 |
-0.7 to 0.7 |
|
-30 |
-22 |
122 |
-0.7 to 0.7 |
|
-20 |
-4 |
72.04 |
-0.6 to 0.6 |
|
-10 |
14 |
44.09 |
-0.6 to 0.6 |
|
0 |
32 |
27.86 |
-0.5 to 0.5 |
|
10 |
50 |
18.13 |
-0.4 to 0.4 |
|
20 |
68 |
12.12 |
-0.4 to 0.4 |
|
30 |
86 |
8.3 |
-0.4 to 0.4 |
|
40 |
104 |
5.81 |
-0.5 to 0.5 |
|
50 |
122 |
4.1 |
-0.6 to 0.6 |
|
60 |
140 |
3.01 |
-0.8 to 0.8 |
|
70 |
158 |
2.23 |
-0.9 to 0.9 |
| High Voltage Battery System |
|
Item |
Specification |
|
Rated capacity (Ah) |
120.6 |
|
Rated voltage (V) |
697 |
|
Rated energy (kWh) |
84 |
|
Cell capacity (Ah) |
60.3 |
|
Composition |
192 (32 modules) |
| High Voltage Charging System |
|
Item |
Specification |
|
Rated voltage (V) |
120 - 230 |
|
Rated current (A) |
6, 8, 10, 12 (Variable Settings) |
| Item |
Specification |
|
| Function |
On-Board Charger (OBC) + Low Voltage DC/DC Converter (LDC) |
|
| OBC system specification |
Maximum capacity (kW) |
10.9 |
|
Input voltage (V) |
AC 70 - 285 |
|
|
Output voltage (V) |
DC 360 - 845 |
|
|
Input current (A) |
Maximum 48 |
|
| LDC system specification |
Maximum capacity (kW) |
2.567 |
|
Input voltage (V) |
DC 288 - 845 |
|
|
Output voltage (V) |
7 - 16 |
|
|
Ampere (A) |
170 |
|
| Cooling |
Cooling type |
Water cooling |
|
Operating temperature [°C (°F)] |
-40 to 85 (-40 to 185) |
|
|
Item |
Specification |
|
Rated voltage (V) |
DC 11 - 13 |
|
Operating voltage (V) |
DC 9 - 16 |
|
Operating temperature [°C (°F)] |
-30 to 85 (-22 to 185) |
|
Parasitic current (mA) |
Maximum 1.0 (Power OFF Mode) |
| Tightening Torque |
| Electric Power Conversion System |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Low voltage (12 V) battery ( - ) terminal |
7.8 - 9.8 |
0.8 - 1.0 |
5.8 - 7.2 |
- |
|
Low voltage (12 V) battery ( + ) terminal |
7.8 - 9.8 |
0.8 - 1.0 |
5.8 - 7.2 |
- |
|
Low voltage (12 V) battery clamp |
9.8 - 13.7 |
1.0 - 1.4 |
7.2 - 10.1 |
- |
|
Low voltage (12 V) battery tray |
9.8 - 13.7 |
1.0 - 1.4 |
7.2 - 10.1 |
- |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Low voltage (12 V) battery ( - ) terminal |
7.8 - 9.8 |
0.8 - 1.0 |
5.8 - 7.2 |
- |
|
Battery sensor |
10.8 - 13.7 |
1.1 - 1.4 |
8.0 - 10.1 |
- |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Inverter assembly |
3.9 - 5.9 |
0.4 - 0.6 |
2.9 - 4.3 |
34.7 - 52.1 |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Wiring protector |
6.9 - 9.8 |
0.7 - 1.0 |
5.1 - 7.2 |
- |
|
Ground cable |
7.8 - 9.8 |
0.8 - 1.0 |
5.8 - 7.2 |
- |
|
Multi inverter assembly |
3.9 - 5.9 |
0.4 - 0.6 |
2.9 - 4.3 |
34.7 - 52.1 |
| High Voltage Battery Control System |
| Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
| Battery Management Unit (BMU) service cover |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| BMU |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| Item |
N·m |
kgf·m |
lb·ft |
lb·in |
| Main fuse ( - ) bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
Front junction box ↔ Power Relay Assembly (PRA) bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
Cell Monitoring Unit (CMU) |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
Main Fuse |
15.7 - 16.7 |
1.6 - 1.7 |
11.6 - 12.3 |
- |
|
Main fuse housing |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
| Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
| Front junction box ↔ Power Relay Assembly (PRA) bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| PRA ↔ Battery Module Assembly (BMA) (+, -) bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| Inverter ( +, - ) bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| Power Relay Assembly (PRA) |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| High Voltage Battery System |
| Item |
N·m |
kgf·m |
lb·ft |
lb·in |
| High voltage battery module disassembly jig |
4.9 - 6.9 |
0.5 - 0.7 |
3.6 - 5.1 |
43.4 - 60.8 |
| Battery Module Assembly (BMA) |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Battery System Assembly (BSA) ground cable |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
BSA penetrate bolt |
68.6 - 88.3 |
7.0 - 9.0 |
50.6 - 65.1 |
- |
|
BSA bolt |
117.7 - 137.3 |
12.0 - 14.0 |
86.8 - 101.3 |
- |
| Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
| High voltage battery system upper case bolt |
103.0 - 154.9 |
10.5 - 15.8 |
75.9 - 114.3 |
- |
|
| Upper Case |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| High voltage junction box connector assembly |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| Integrated Charging Control Unit (ICCU) connector service cover |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| ICCU connector assembly |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| Battery Management Unit (BMU) connector assembly |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
| Main fuse ( - ) bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| Front junction box ↔ Power Relay Assembly (PRA) bus bar |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| bus bar between battery modules |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
| Mounting bracket |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| Sub Battery Pack Assembly (Sub-BPA) |
1st |
8.8 |
0.9 |
6.5 |
- |
|
2nd |
10.8 |
1.1 |
8.0 |
- |
|
| High Voltage Charging System |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Charge junction box unit |
9.8 - 11.8 |
1.0 - 1.2 |
7.2 - 8.7 |
- |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Quick charge connector service cover |
4.9 - 7.8 |
0.5 - 0.8 |
3.6 - 5.8 |
43.4 - 69.4 |
|
Quick charge connector |
9.3 - 10.3 |
0.95 - 1.05 |
6.9 - 7.6 |
- |
|
Ground cable |
10.8 - 13.7 |
1.1 - 1.4 |
8.0 - 10.1 |
- |
|
Charger inlet assembly protector |
4.9 - 7.8 |
0.5 - 0.8 |
3.6 - 5.8 |
4.34 - 69.4 |
|
Charger inlet assembly |
6.9 - 9.8 |
0.7 - 1.0 |
5.1 - 7.2 |
- |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Low Voltage DC/DC Converter (LDC) ( - ) cable |
7.8 - 9.8 |
0.8 - 1.0 |
5.8 - 7.2 |
- |
|
LDC ( + ) cable |
7.8 - 9.8 |
0.8 - 1.0 |
5.8 - 7.2 |
- |
|
Integrated Charging Control Unit (ICCU) |
19.6 - 23.5 |
2.0 - 2.4 |
14.5 - 17.4 |
- |
|
ICCU pad |
3.9 - 5.9 |
0.4 - 0.6 |
2.9 - 4.3 |
34.7 - 52.1 |
|
ICCU fuse service cover |
7.8 - 11.8 |
0.8 - 1.2 |
5.8 - 8.7 |
- |
|
ICCU fuse cover |
2.0 - 2.9 |
0.2 - 0.3 |
1.4 - 2.2 |
17.4 - 26.0 |
|
ICCU fuse |
3.9 - 4.9 |
0.4 - 0.5 |
2.9 - 3.6 |
34.7 - 43.4 |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Vehicle Charge Management System (VCMS) bracket |
6.9 - 9.8 |
0.7 - 1.0 |
5.1 - 7.2 |
- |
|
VCMS |
9.8 - 11.8 |
1.0 - 1.2 |
7.2 - 8.7 |
- |
| High Voltage Distributing System |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Front high voltage junction box |
4.9 - 7.8 |
0.5 - 0.8 |
3.6 - 5.8 |
43.4 - 69.4 |
|
Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
Wiring protector |
6.9 - 9.8 |
0.7 - 1.0 |
5.1 - 7.2 |
- |
|
High voltage junction box service cover |
3.9 - 5.9 |
0.4 - 0.6 |
2.9 - 4.3 |
34.7 - 52.1 |
|
High voltage junction box ground bolt |
6.9 - 9.8 |
0.7 - 1.0 |
5.1 - 7.2 |
- |
|
Front high voltage junction box |
6.9 - 9.8 |
0.7 - 1.0 |
5.1 - 7.2 |
- |
| Item |
N·m |
kgf·m |
lb·ft |
lb·in |
|
| Rear high voltage junction box bolt |
15.7 - 23.5 |
1.6 - 2.4 |
11.6 - 17.4 |
- |
|
| High voltage cable |
15.7 - 23.5 |
1.6 - 2.4 |
11.6 - 17.4 |
- |
|
| High voltage junction box service cover |
3.9 - 5.9 |
0.4 - 0.6 |
2.9 - 4.3 |
34.7 - 52.1 |
|
| Rear high voltage junction box and inverter bolt |
6.9 - 9.8 |
0.7 - 1.0 |
5.1 - 7.2 |
- |
|
| Rear high voltage junction box |
Bolt |
15.7 - 23.5 |
1.6 - 2.4 |
11.6 - 17.4 |
- |
|
Nut |
17.7 - 26.5 |
1.8 - 2.7 |
13.0 - 19.5 |
- |
|
Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: If You Have a Flat Tire (with Tire Mobility Kit)
The Tire Mobility Kit (TMK) supplied with the Kia EV6 is intended as a temporary emergency repair solution. Following use of the kit, the damaged tire should be professionally inspected, repaired, or replaced by an authorized Kia dealer as soon as possible. Compressor Sealant bottle Before using the Tire Mobility Kit on your Kia EV6, carefully read all instructions and safety information contained in this section to ensure proper operation and maximum effectiveness.Kia EV6 (CV/CV1A) 2022-2026 Workshop Manual: Power liftgate: (if equipped)
Power liftgate operating conditions The Kia EV6 power liftgate system operates when the vehicle is in P (Park) while running. When the vehicle is turned off, the power liftgate can still operate regardless of gear position. For safety reasons, the liftgate only opens when vehicle speed remains below 1.8 mph (3 km/h). Before using the Kia EV6 power liftgate, always confirm that the vehicle is securely shifted into P (Park).